15-15
15
15.3 Waste Solution System
Removal
1. Shut down the system by performing the post-
operational checks and turn OFF the built-in
circuit breaker and the main power supply.
2. Remove the screw and then the waste solution
level sensor cover.
3. Disconnect the sensor connector.
NOTE: If the space is narrow between the machine and the
wall, put the flashlight from above and look through
the slits (peep holes) in the right cover.
4. Remove the waste solution tank cap.
5. Remove the two screws and then the sensor from
the tank cap.
Installation
Installation is essentially in the reverse order of removal.
15.3.1
Waste Solution Level Sensor (FS728) Replacement
LII665
Screw
Waste Solution Level Sensor Cover
LII1191
Flashlight
Slits (Peep Holes)
Connector
Tank Cap
LII667
Screws (2)
Sensor (FS728)