10-6
10.2 Upper Paper Magazine Table
Removal
1. Remove the upper magazine setting lever
.
2. Remove the four screws and then the lock
assembly.
3. Remove the spring, E-ring, two poly-sliders and
arm.
Installation
Installation is essentially in the reverse order of
removal.
Removal
1. Open the magazine door.
2. Align the holes by sliding the magazine table and
remove the following screws.
• Eight screws securing the rail to the cutter side
bracket
• Eight screws securing the center rail to the
frame
• Eight screws securing the rail to the processor
side bracket
3. Remove the upper magazine table unit.
10.2.3
Upper Magazine Setting Lever Lock Arm Replacement
LII374
Screws (4)
Lock Assembly
LII375
E-ring
Poly-sliders (2)
Spring
Arm
10.2.4
Upper Magazine Table Unit Removal/Reinstallation
LII376
Screws (8)
Screws (8)
Screws (8)