5-9
5.2 System Operation Setup and Check (01)
5
1) Select “YES” for “Preheat Setting”.
• The 1st and 2nd preheat setting boxes appear.
2) Move the cursor to “1st Preheat” and enter the
time.
3) Move the cursor to “2nd Preheat” and enter
the time.
NOTE: • For preheating once only, set the same time
for both the first and second times.
• Select “NO” when the preheat timer is not
used.
• The second preheating timer is ignored if the
first preheat time and second preheat time
overlap.
<Example> 1st. pre-heat time: 2:00AM
2nd. pre-heat time: 3:00AM
With the above settings, nighttime
preheating will occur from 2:00AM to
4:00AM (2 hours).
4. Click the [OK] button.
• Operation returns to the menu screen.
This procedure makes a backup of the data stored on
the hard disk of the main control unit when data,
indicated on the data sheet located inside the front
upper cover, is changed.
The backup floppy disks are used when reinstalling or
reverting to earlier system software.
[Selection]
[Setup and Maintenance]
→
[01 System Operation
and Check]
→
[0122 Data Backup]
1. Prepare a new floppy disk for data backup when
backing up data.
NOTE: A floppy disk is unnecessary for pricing unit data
backing up because data is backed up to the
hard disk of the main control unit.
2. Insert the floppy disk into the floppy drive of the
main control unit.
5.2.5
Data Backup (0122)