4-6
4.2
Update
In the “Update”, the FRONTIER 570 System Software
(A1) is upgraded.
When the following circuit board is replaced, also
perform the “Update”.
SP-3000:
GMB23, CTB23, CLE23 or CPZ23 circuit board
LP5700:
GMC23 circuit board
IMPORTANT:
If the “Free space in the hard disk is insufficient”
message appears, delete the variety print service
template data.
1. Select “NO” for “Rack Auto Cleaning” on Menu
0625 “Processor Operating Condition Setup”.
2. Remove the carrier.
3. Insert the FRONTIER 570 System (A1) Disk into
the CD-ROM drive.
4. Shut down the system by performing the post-
operational checks.
5. Turn the power switch ON to start up the Printer/
Processor and then to STANDBY.
Z
2
051
Handles
Auto Film Carrier
NC100AY
Film Carrier
Lock Release
Lever
Z
2
043
FRONTIER 570
System (A1) Disk