FinePix S602 ZOOM SERVICE MANUAL
4. Adjustment
51
4-4.Adjustment of Components (for PC adjustment)
4-4-1.Starting the Adjustment Software (cautions during use)
Procedure
1) When the initial setup for the adjustment software (see 4-3-6.) is complete, terminate [FFW.exe] and start it again.
2) <Notes when using adjustment software> appears on the screen.
3) Press the [Enter] key on the PC and set the camera in the jig mode in accordance with the instructions on the screen.
4-4-2.Camera Jig Mode Procedure
Procedure
1) Set the mode dial to the [SET-UP] mode.
2) Open the card cover.
3) Connect the camera to the PC using the USB cable.
4) Connect the power supply cable jig to the camera to supply 5.00+/-0.01V.
5) While pressing the shutter button, set the power switch to [Photography] mode.
6) The camera is in the Jig mode if the LED beside the card cover is green.
<Fig.1>Program Start-up Screen
<Fig.2>Camera Jig Mode Setup Procedure Screen
FxS602Z.ff
FinePix S602 Zoom PC adjustment software
<Notes when using adjustment software>
1) The content of the adjustment is different
because of replaced parts.
2) Refer to the service manual for the adjustment done
after parts are replaced.
3) Use [Power supply cable jig] at all the adjustments.
4) Execute the end setting when using this adjustment software.
5) Notes have been described to the service manual besides the
above-mentioned, and advance the adjustment after it refers.
Advance to the jig mode setting screen
when you press [Enter] key of PC.
FxS602Z.ff
FinePix S602 Zoom PC adjustment software
1) Set the mode dial to the [SET-UP] mode.
2) Open the card cover.
3) Connect the camera to the PC using the USB cable.
4) Connect the power supply cable jig to the camera
to supply 5.00V+/-0.01V.
5) While pressing the shutter button,
set the power switch to [Photography] mode.
6) The camera is in the Jig mode
if the LED beside the card cover is green.
Press [Enter] key of PC when the procedure of 1-6 is completed.
*1 : The PC is not recognized as a removable disk when connected with the camera in the Jig mode.
*2 : If NG occurs during camera adjustment and the software is terminated, remove all cables and com-
mence adjustment again.
*3 : Select [Final Setting] in the adjustment software to terminate the camera Jig mode.