Premium DC Inverter Series Cassette Type Unit
34
Table 7.1
Failure
Possible Reasons
The unit cannot be
started.
①
. The power supply is not connected.
②
. Electrical leakage of air-conditioning unit causes tripping of the
leakage switch.
③
. The operating keys are locked.
④
. The control loop has failure.
The unit operates for a
while
and then stops.
①
. There is obstacle in front of the condenser.
②
. The control loop is abnormal.
③
. Cooling operation is selected when the outdoor ambient temperature
is above 48°C.
Poor cooling effect.
①
. The air filter is dirty or blocked.
②
. There is heat source or too many people inside the room.
③
. The door or window is open.
④
. There is obstacle at the air intake or outlet.
⑤
. The set temperature is too high.
⑥
. There is refrigerant leakage.
⑦
. The performance of room temperature sensor becomes worse
Poor heating effect
①
. The air filter is dirty or blocked.
②
. The door or window is not firmly closed.
③
. The set room temperature is too low.
④
. There is refrigerant leakage.
⑤
. The outdoor ambient temperature is lower than -5°C.
⑥
. Control loop is abnormal.
Note:
After carrying out the check of the above items and taking relevant measures to
solve the problems but the air-conditioning unit still does not function well, please stop
the operation of the unit immediately and contact the local service agency designated
by Fujidenzo. Only ask professional serviceman to check and repair the unit.
7.2 Routine Maintenance
Only a qualified service person is allowed to perform maintenance.
Before accessing to terminal devices, all power supply circuits must be
disconnected.
Do not use water or air of 50°C or higher for cleaning air filters and outside panels.
Notes:
①
. Do not operate the air conditioner with the filter uninstalled, otherwise dust
would come into the unit.
②
. Do not remove the air filter except for cleaning. Unnecessary handling may
damage the filter.
Содержание FIC180G IN