Premium DC Inverter Series Cassette Type Unit
33
3). “88” Display:
When there is no error, and it receives valid remote control information. It will
display the temp setup for 5s, then display the temp of indoor. When the unit has error,
It will display the error code. When there are more than one error, the error code will be
displayed alternately.
After the grille of the front panel is opened, the front panel is still allowed to realize
the following functions by pressing the “Auto” button and the nearby “Test” button
simultaneously for five seconds when the unit is “Off”.
6.2 Working Temperature Range
Table 6.2
Test Condition
Indoor Side
Outdoor Side
DB(°C)
WB(°C)
DB(°C)
WB(°C)
Nominal Cooling
27
19
35
24
Nominal Heating
20
−
7
6
Rated Cooling
32
23
48
−
Low Temp. Cooling
21
15
-15
−
Rated Heating
27
−
24
18
Low Temp. Heating
20
−
-10
-11
Note:
①
. The design of this unit conforms to the requirements of ISO5151 standard.
②
. The air volume is measured at the relevant standard external static pressure.
③
. Cooling (heating) capacity stated above is measured under nominal working
conditions corresponding to standard external static pressure. The
parameters are subject to change with the improvement of products, in which
case the values on nameplate shall prevail.
7 Troubleshooting and Maintenance
7.1 Troubleshooting
If your air-conditioning unit suffers from abnormal operation or failure, please first
check the following points before repair: