Error Code
503
Pro
b
lem
So
lv
in
g
15
021-500
[Cause]
The following operation is performed when the Auditron mode for the Fax service is
enabled.
z
While a Send Fax job is processing, another job that the Auditron mode is enabled
starts.
z
While another job that the Auditron mode is enabled is processing, a Send Fax job
starts.
[Remedy] Wait for the active job finishes, and start the next job.
021-501
[Cause]
The communication with the EP system via the internet failed.
[Remedy] Switch off the machine power, make sure that the touch screen is blank, and then switch
on the machine power. If the error still is not resolved, contact our Customer Support
Center.
021-502
[Cause]
An error occurred while connecting to the EP system via the Internet. There is a problem
with the address of the EP proxy server name.
[Remedy] Switch off the machine power, make sure that the touch screen is blank, and then switch
on the machine power. Execute the operation again. If the error still is not resolved,
contact our Customer Support Center.
021-503
[Cause]
An error occurred while connecting to the EP system via the Internet. There is a problem
with the address of the EP proxy server name.
[Remedy] Check the followings:
z
LAN cable connection
z
DNS server address setting
z
The default gateway setting
z
The subnet mask setting
If the error still is not resolved after checking the above settings, there may be a network
failure or the proxy server settings may be changed or failed. Consult your system
administrator.
If the network works normally but the error still is not resolved, contact our Customer
Support Center.
021-504
[Cause]
An error occurred while connecting to the EP system via the Internet.
[Remedy] Check the followings:
z
LAN cable connection
z
DNS server address setting
z
The default gateway setting
z
The subnet mask setting
If the error still is not resolved after checking the above settings, there may be a network
failure or the proxy server settings may be changed or failed. Consult your system
administrator.
If the network works normally but the error still is not resolved, contact our Customer
Support Center.
021-505
[Cause]
The SSL/TLS communication with the EP server failed.
[Remedy] Switch off the machine power, make sure that the touch screen is blank, and then switch
on the machine power. If the error still is not resolved, contact our Customer Support
Center.
021-506
[Cause]
The SSL Certificate for the EP server is incorrect.
[Remedy] Switch off the machine power, make sure that the touch screen is blank, and then switch
on the machine power. Execute the operation again. If the error still is not resolved,
contact our Customer Support Center.
Error Code
Cause and Remedy
Содержание ApeosPort-V 6080
Страница 1: ...ApeosPort V 7080 ApeosPort V 6080 DocuCentre V 7080 DocuCentre V 6080 Administrator Guide ...
Страница 13: ...13 Activity Report 727 EP System 731 Glossary 732 Index 735 ...
Страница 14: ...14 ...
Страница 62: ...2 Paper and Other Media 62 Paper and Other Media 2 ...
Страница 88: ...3 Maintenance 88 Maintenance 3 ...
Страница 110: ...4 Machine Status 110 Machine Status 4 ...
Страница 296: ...5 Tools 296 Tools 5 ...
Страница 346: ...9 Scanner Environment Settings 346 Scanner Environment Settings 9 ...
Страница 354: ...10 Using IP Fax SIP 354 Using IP Fax SIP 10 ...
Страница 366: ...12 Using the Server Fax Service 366 Using the Server Fax Service 12 ...
Страница 382: ...13 Encryption and Digital Signature Settings 382 Encryption and Digital Signature Settings 13 ...
Страница 734: ...16 Appendix 734 Appendix 16 ...
Страница 744: ...Index 744 Index ...