23
Program status display (display only)
〜
No. 1 to 4 target value
〜
No. 1 to 4 ramp time
〜
No. 1 to 4 soak time
[Description]
• This is a function to change set value
(SV) with time automatically ac-
cording to preset pattern. Up to 4
ramp/soak data can be programmed.
• No. 1 ramp starts from measurement
value (PV) just before the program
is executed.
• It is also possible to run the program
automatically at power ON (power
ON start function).
Example) Set No. 1 target value to 400
°
C
Key operation
Description
Press the SEL key to display P.
Press the SEL key repeatedly until
SV-1 is displayed.
Press the or key to display
400
°
C.
Press the DATA key to display data.
Press the SV key when you need to
display the operation status display.
After pressing the ENT key, the
data is registered.
Display
SEL
ENT
SV
DATA
SEL
Ramp .... Time to change in set value
toward target value.
Soak ..... Time not to change set value
as it is set to target value.
[Parameters]
To execute this function, the program
should be set in advance. It can be set
by setting the required set value (SV)
in the parameters shown in the table
at right.
Related parameter: ProG (Page 24)
SV3
Set
value
SV2
SV1
SV4
PV
TM1R
No.1
ramp
TM1S
TM2S
TM2R
TM3R
TM4R
TM3S
No.1
soak
No.2
soak
No.3
soak
TM4S
Time
No.4
soak
No.2 ramp
No.3 ramp
No.4 ramp
Parameter
display
symbol
Initial
value at
delivery
Name
STAT
SV-1
SV-4
TM1r
TM4r
TM1s
TM4s
Mod
—
0
0.00
0.00
0
Description
Remarks
〜
〜
〜
Actual program
position
No.1 to 4 ramp
target value
No.1 to 4 ramp
time
No.1 to 4 soak
time
Ramp SV mode
The state of program execution is displayed.
This parameter is used only for display and
cannot be used for setting.
Not displayed when ramp/soak is not given.
Target value (SV) of each ramp time can be
set.
(Setting range: 0 to 100%FS)
Each ramp time can be set.
(Setting range: 0 to 99 hour and 59 minute)
Used for selection of mode of ramp/soak
function. Normally it is set to “0”.
〜
〜
〜
Stop
No.1 to 4 ramp under execution
No.1 to 4 soak under execution
Program end
〜
〜