![Fuji Electric POD UG Series Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/fuji-electric/pod-ug-series/pod-ug-series_user-manual_2341805021.webp)
2
1. Specifications
2-5
S
Function Performance Specifications
*1
The number of setting memory locations is limited to 256 per screen.
*2
Layer: 4 per screen (base + 3 overlaps)
Item
Specifications
Screens
Max. 1024
Screen Memory
Flash memory: Appox. 760 kbyte (varies depending on the font)
Switch
192 per screen
Switch Actions
Set, reset, momentary, alternate, to light
(Possible to press a function switch and a switch on the display at the same time)
Lamps
Reverse, blink, exchange of graphics
192 per screen
Graphs
Pie, bar, panel meter and closed area graph:
No limitation within 128 kbyte per screen
*1
Statistics and trend graphs:
Max. 256 per layer
*2
Data
Setting
Numerical Data Display
No limitation within 128 kbyte per screen
*1
Character Display
No limitation within 128 kbyte per screen
*1
Message Display
Resolution:
Max. 40 characters (1-byte)
No limitation within 128 kbyte per screen
*1
Sampling
Sampling display of buffer data
(Constant sample, bit synchronize, bit sample, relay sample, alarm function)
Graphic Library
Max. 2560
Multi-Overlaps
Max. 1024
Data Blocks
Max. 1024
Messages
Max. 6144 lines
Patterns
Max. 1024
Macro Blocks
Max. 1024
Page Blocks
Max. 1024
Direct Blocks
Max. 1024
Screen Blocks
Max. 1024
Screen Library
Max. 1024
Temperature Control
Network/PLC2Way Table
Max. 32
Time Display
Time display function: provided
Buzzer
Buzzer: provided, 2 sounds (short beep, long beep)
Auto OFF Function
Always ON, random setting
Self-diagnostic Function
Switch self-test function
Communication parameter setting check function
Communication check function
Содержание POD UG Series
Страница 9: ...11 Features 2 Models and Peripheral Equipment 3 System Composition Overview...
Страница 15: ...1 6 3 System Composition Please use this page freely...
Страница 28: ...2 12 5 Modular Jack MJ1 Please use this page freely...
Страница 29: ...31 Mounting Procedure 2 Power Supply Cable Connection Installation...
Страница 32: ...41 Coin type Lithium Battery UG221H SR4 and LR4 only 2 DIP Switch Setting 3 Function Switches Instructions...
Страница 48: ...61 Operational Procedures 2 Main Menu Screen Simple POD Operations...
Страница 65: ...71 Error Messages 2 Troubleshooting Error Correction...
Страница 72: ...81 Inspection and Maintenance 2 Warranty Policy Inspection and Maintenance...