
Chapter 2 Description of Functions
77
2.3.3.8. Sub Window
[ 1 ] Cursor
Each box in the cursor sub window shows the channel setting values or status at each cursor
position.
Cursor values at analog Channel
Settings on cursors
Cursor B
Cursor A
Cursor value monitor
vertical slide bar
Cursor values at
digital Channel
Select cursor display
Vertical: Two cursors (Cursor A, Cursor B, Cursors A and B)
Horizontal: Two cursors (Cursor A, Cursor B, Cursors A and B)
No display
Cursor value monitor
Analog channel: 8 channels
Digital channel: 16 channels
(You can display the hidden portions using the cursor value monitor vertical slide bar.)
Use the scroll bar to move to the waveform screen to be analyzed and click the point to be
observed in the graph. The cursor will move to that position. The cursor movement position is
the sampling point (time point) closest to the clicked point. The trace data of all channels on the
cursor appears in the measurement monitor.
Alternatively, you can move the cursor using the cursor movement bar or by dragging the mouse.
The cursor keys on the keyboard are also available.
However, while tracing, neither waveform screen nor cursor can be moved.
Содержание Frenic
Страница 118: ...MEMO...