2.2 Before setting the function code
Set the function code in following order.
Otherwise, a different value might be set.
1.
C21 (Speed Command Unit) should be set.
The speed can be specified by the selected unit.
C21 data
Speed Command Unit
Related function code
0
r/min
P01
1
m/min
P01, F03, L31
2
Hz
None
3
mm/s
P01, F03, L31
2.
P01 (Motor, Number. of poles) should be set.
3.
F03 (Rated Speed) and L31 (Elevator Parameter, Speed) should be set.
F03 (Rated speed) depends on P01 (motor, number of poles). Set the date of F03 again
when you change P01. For details, refer to the descriptions of function codes F03.
Changing any data of C21, P01, F03 and L31 requires modifying again the data of the function codes
listed below.
Function code(Name)
Inverter
internal value
[Hz]
Function code(Name)
Inverter
internal value
[Hz]
F04(Base Speed)
1.00 to 200.0
C03 Battery Operation Speed)
0.00 to 200.0
F20(DCB Starting Speed)
0.00 to 5.00
C04(Zero Speed) to C19(High
Speed 9)
0.00 to 200.0
F23(Starting Speed)
0.00 to 5.00
C20(Jogging Operation Speed)
0.00 to 200.0
F25(Stop Speed)
0.00 to 5.00
H74((Speed Agreement, Hysteresis)
0.00 to 200.0
E30(Speed Arrival, Hysteresis)
0.00 to 200.0
L30((Short Floor Operation,
Allowable speed)
0.00 to 200.0
E31(Speed Detection, Detection
level)
0.00 to 200.0
L40(ASR, Switching speed 1)
0.00 to 200.0
E32(Speed Detection, Hysteresis)
0.00 to 30.00
L41(ASR, Switching speed 2)
0.00 to 200.0
E36(Speed Detection 2, Detection
level)
0.00 to 200.0
L87((Door Control, Door open
starting speed))
0.00 to 200.0
Relational expression of r/min and Hz
[r min
⁄
] = 120 ×
[Hz]
𝑃𝑃𝑃𝑃
Relational expression of mm/s and Hz
[mm s
⁄
] =
Vmax
Nmax × 120 ×
[Hz]
𝑃𝑃𝑃𝑃
Relational expression of m/min and Hz
[m min
⁄
] =
Vmax
Nmax × 120 ×
[Hz]
𝑃𝑃𝑃𝑃
×
60
1000
Symbols definition:
Pe
: P01(Motor, No. of poles) (pole)
Nmax
: F03 (Rated Speed) (r/min)
Vmax
: L31 (Elevator Speed) (mm/s)
2-22
Содержание Frenic lift
Страница 1: ...LM2A series Reference Manual INR SI47 1909a E...
Страница 7: ......
Страница 13: ......
Страница 51: ...2 38...
Страница 221: ......
Страница 242: ...3 4 Programming Mode Chap 3 OPERATION USING TP A1 LM2 Figure 3 14 Screen transition for Op Monitor display example 3 21...
Страница 252: ......
Страница 254: ...URL http www fujielectric com...