background image

Unless otherwise specified, "raise" and "lower" means

raising and lowering the press ram.

Power source

This press requires 100 VAC

±

10%, 50/60 Hz.

CAUTION:

Connecting a power supply that is different from

this specification may cause a fire or result in bodily injury.

Supplied air pressure

The compressed air pressure used with this press should be 0.2 to

0.5 MPa.

CAUTION:

Use of compressed air at pressures greater than 0.5

MPa may cause the pipes or hoses to burst.

Workbench

WARNING:

Use this press only after securing it on a working

bench that is sturdy enough to support the weight of the press. If it

is not secured, the machine may fall and injure someone.

Acrylic safety cover

WARNING:

Make sure to install the acrylic safety cover on the

mechanical stopper before operation. If you operate the press

without the cover, people may become entangled in the press.

A d j u s t m e n t

o f

t h e

WARNING:

Adjust the mechanical stopper only when the press

mechanical stopper

ram has been raised and is stopped. Make sure that no one is near

the controls. If anyone operates the controls while you are adjusting

the mechanical stopper, you may be injured.

Press operation (1)

Before starting operation, make sure that no one is touching any

part of the press. Especially, when matching mold parts, or when

more than one worker is involved in press preparations, he/she may

be injured. Never touch the mechanical stopper, jig, metal die,

rotation stopper arm, photo sensor light shielding plate, etc.

WARNING:

When two or more people are working near a

press, they must use a sysytem for communicating that leaves no

doubt of their intent. The chances for an accident increase if there is

a misunderstanding about what action will take place next. In a

noisy work environment, hand signals can be used. Failure to

communicate clearly with people in the immediate area can result in

accidents, serious injury and even death.

Press operation (2)

When operating the press, make sure to push both Two-handed

pushbutton switches, one with each hand. If you modify or disable

either of the two switches, or if you set up a foot switch to operate

the press, you may become caught in the jig or metal die and you

may be injured. If you have to operate the press using only one

hand, or by using a foot switch, equip the press with a light beam

interlock device to ensure the safety of the operator. (Make sure to

consult us about these kinds of operations before working this area.)

WARNING:

Pneumatic presses have moving parts that can

crush you and you can die. Make sure to stay clear of any press

while it is moving. Turn of all electrical and pneumatic sources of

power before attempting to adjust the machine.

Содержание FCP-100

Страница 1: ...1000 Ver 3 01 Make sure to read this manual before using this press Then store it in a safe location The specifications may be changed without prior notice FUJI CONTROLS CO LTD 1 5 6 Iidabashi Chiyod...

Страница 2: ...ill be using the machine outside Japan make sure to follow the safety regulations in the country where the press will be used GENERAL WARNING Pneumatic presses are dangerous machines if not handled ca...

Страница 3: ...the press Especially when matching mold parts or when more than one worker is involved in press preparations he she may be injured Never touch the mechanical stopper jig metal die rotation stopper ar...

Страница 4: ...supply inlet Instruction manual CAUTION If you sell or loan the press to someone else make sure to give them this instruction manual Modifications disassembly WARNING Never modify disassemble or repai...

Страница 5: ...n Method 3 2 Preparation 3 Adjustment of each section 3 1 Mold Matching inching operation 3 2 Stroke Adjustment 4 Options 4 Maintenance 5 Spare parts 5 Wiring diagram 6 Diagrams of Air circuit 6 Speci...

Страница 6: ...uick exhaust valve This valve increases the exhaust capacity of air This unit is installed only on the FCP 750H Acrylic safety cover A safety cover used to keep body parts from getting caught between...

Страница 7: ...filter and regulator Dirty water may splash out when opened Put a cup under the drain to catch the water when you open it Two handed pushbutton switches Both switches must be pressed at the same time...

Страница 8: ...air line The available air pressure should be from 0 2 to 0 5 MPa Adjust the air pressure using a regulator to achieve the required output for the press See page 10 Press output chart 3 Then connect t...

Страница 9: ...revent the press from hitting bottom if no workpiece is present 2 Set the press fit dimension thickness of a workpiece by adjusting the press stroke 3 Adjust the Press Output and Lowering Speed 1 The...

Страница 10: ...FCP 750H FCP 1000 Suppliers QuickExhaust Valve AQ400 03 SMC SpeedControoller AS2201F 02 08S AS4000 02 AS4000 03 AS4000 03 AS4000 02 SMC Sorenoid Valve VF1120 1GC 01 VP342 1G 01 VT325 021G VT325 021G...

Страница 11: ...i le nce r FCP 100 FCP 200 and FCP 500 The air tank is not installed on the FCP 200 Pushbutton Switch Pushbutton Switch Solenoid Valve Plug Terminal Block Solenoid Valve Two handed Pushbutton Switches...

Страница 12: ...hing Val ve Fi lter Reg ulat r A ir O utle t Sile ncer Spee d Co ntro ller Sol enoi d Va lve Solenoid Valve Silencer Air tank Filter Regulatr Air Outlet Inching Valve Speed Controller Quick Exhaust Va...

Страница 13: ...200 235 280 285 285 L mm 245 280 300 305 305 M mm 25 50 25 50 25 50 25 60 25 50 N mm 125 140 145 200 200 O mm 150 170 180 230 230 P mm 420 420 450 450 450 a mm 15 H9 15 H9 15 H9 20 H9 20 H9 b mm 25 28...

Страница 14: ...rent Power of Solenoid Valve unit VA FCP 100 FCP 200 FCP 500 FCP 750H FCP 1000 In rush 6 6 75 75 100 Holding 4 4 27 27 20 3 Air Consumption unit NI FCP 100 FCP 200 FCP 500 FCP 750H FCP 1000 1 4 1 5 3...

Страница 15: ...10 0 0 0 0 4 0 Press output Press output Press output Press output Supplied air pressnre Supplied air pressnre Press output Supplied air pressnre Supplied air pressnre Supplied air pressnre...