6
GB
Connect the cables from the Quattro LNB to the input connectors
2
Lo
vertikal
Hi
Hi
horizontal
Lo
1
Lo
vertikal
Hi
Hi
horizontal
Lo
(pay attention to identification of the Quattro LNB connectors)
The multiswitch is equipped with Terrestrial input. Connect
the Terrestrial antenna to this input::
terr.
There are two output connectors:
2 x
Standard
Legacy
and 1 x
The Legacy outputs are standard Universal switching outputs which allow to connect two
legacy receiver which are not supporting the Unicable protocol.
The Unicable output allows to connect up to eight receiver tuners – each receiver tuner
is assigned with one out of eight communication channel frequencies (user band).
User Bands:
0 – 1076,06 MHz
4 – 1484,30 MHz
1 – 1178,12 MHz
5 – 1586,36 MHz
2 – 1280,18 MHz
6 – 1688,42 MHz
3 – 1382,24 MHz
7 – 1790,48 MHz
For optimized performance, please follow the recommendations below:
• Use the highest frequency for a wall socket located nearest to the multiswitch and use the
lowest frequency for wall socket located farest to the multiswitch.
• If you install less than eight receiver tuners, use the lowest frequencies first.
• We also recommend to keep record of the user bands allocated to the different
connections as these user bands will then have to be set in the receiver.
The satellite receivers connected to the multiswitch have to be
Unicable-compatible (usually marked with Unicable™ logo).
Note: Loopthrough outputs that are not used should be
terminated with 75ohm DC-blocked terminations.
Safety
• Never open a powered product. This may result in electrical hazard !
• Never work on the product, TV set or other powered devices during or before a storm.
A lightning strike into the antenna may cause dangerous overvoltage over the product’s
metallic/conductive parts.
• Make sure the local electricity network corresponds to the operating voltage of the
AC/DC adaptor.
• If the products gets into contact with liquid it must be disconnected from the main power.
• It is recommended to disconnect the product from the main power if it is not used for long
periods of time.
• The product shall be serviced by qualified experts only.