background image

Temperature and Humidity Sensor 

 

Page 7/15 

700-THS3    Rev. 6 -05 May 2015  

3.

 

In the northern hemisphere, position the support arm so that the sensor is positioned south 
of the mast and on the north side of the solar panel to ensure neither pieces of equipment 
will be shaded.  In the southern hemisphere, the positioning will be opposite. 

 

 

Figure 2-3:  Support arm positioning (northern hemisphere) 

(Note: support arm may not appear exactly as shown) 

4.

 

Attach the sensor cable to the support arm and the mast using cable ties. 

5.

 

Connect the sensor cable to the data logger’s Temperature / Humidity connector (red ring). 

 

NOTE: Key Installation Points: 

a)

 

The  sensor  should  be  in  the  open,  in  a  shade  free  area  to  ensure 
accurate temperature readings. 

b)

 

The sensor should be well away from external sources of heat (i.e. any 
equipment at the site that might generate heat). 

c)

 

The sensor should be given a minimum of thirty minutes to acclimatize 
to a site after installation before data is taken. 

2.3

 

Maintenance 

FTS recommends that the sensor be returned to FTS for a yearly check of the THS-3 sensor’s 
calibration.   
Also, FTS recommends that during any site visit a visual check of the THS-3 cable, connector and 
sensor filter is performed.  Any observable damage should be noted so that the appropriate repairs 
can be performed.  The THS-3 sensor filter (FTS part number: 03-THS3-6192) is field replaceable in the 
event that the sensor filter is clogged. 
Please contact FTS technical support if the unit ceases to operate properly. 

Solar Panel 

Содержание THS-3

Страница 1: ...1 800 548 4264 www ftsenvironmental com 700 THS3 Rev 6 05 May 2015 THS 3 Temperature and Humidity Sensor Installation and Quick Setup Guide...

Страница 2: ...ental com 700 THS3 Rev 6 05 May 2015 Contact information FTS 1065 Henry Eng Place Victoria B C V9B 6B2 CANADA www ftsenvironmental com Toll free 1 800 548 4264 Local 250 478 5561 Technical support htt...

Страница 3: ...1 General Description 3 1 2 Specifications 4 Chapter 2 Installation and Maintenance 5 2 1 General 5 2 2 Tower Mounting 5 2 3 Maintenance 7 Chapter 3 Sensor Quick Setup Guide 9 3 1 Configuring the THS...

Страница 4: ...humidity 0 to 1 Vdc equals 0 to 100 RH on the sensor connector The T H sensor assembly see Figure 1 1 houses the sensors and associated electronics Both sensors are protected from air borne contamina...

Страница 5: ...und Power Humidity Output K Temperature Ground thermistor others No Connect Table 1 THS Sensor Signal Connections 1 2 Specifications The specifications for the THS 3 Temperature and Humidity Sensor ar...

Страница 6: ...eight Correct installation height is dependent on regulations for the jurisdiction in which the equipment is to be deployed Ensure you review local regulations prior to installation In the United Stat...

Страница 7: ...2015 Figure 2 1 Attaching the assembly to the support arm 2 Loosely attach the support arm to the mast or tower with the clamp bolts at the desired sensor height Ensure the support arm s V is fitted t...

Страница 8: ...n the open in a shade free area to ensure accurate temperature readings b The sensor should be well away from external sources of heat i e any equipment at the site that might generate heat c The sens...

Страница 9: ...en key to remove the three bolts securing the base of the sensor to the base plate of the housing assembly Figure 2 4 Sensor base showing bolts c Gently remove the sensor and inspect the filter for cl...

Страница 10: ...ce NOTE After installation the sensor should be given a minimum of thirty minutes to acclimatize to a site before data is taken 3 1 Configuring the THS 3 1 Connect the THS 3 to the data logger on the...

Страница 11: ...t select the F radial button Humidity This is the relative humidity Clip at 0 100 If checked causes the datalogger to limit humidity values read from the sensor to the range of 0 to 100 That is any ai...

Страница 12: ...Line Logging does not have the full functionality as setting up Logging through the Data screen 1 Select the Edit button then Input the desired the Logging Interval press on the hour minute or second...

Страница 13: ...bed here are displayed in blue Logging intervals created using the In line Logging feature are displayed in green Figure 3 6 Logging Intervals 3 Press the Add icon then the Edit icon Set the desired l...

Страница 14: ...he Home page 3 4 Confirm Sensor Operation Now that the THS 3 is setup confirm its operation and ensure data is being logged 1 From the Home page select the Data icon to display the Data Status screen...

Страница 15: ...turn to the Home page 3 5 Changing the Setup If you want to change the setup from the Home page select the blue Sensors icon then select the THS icon Select the Set up Cog which will bring you to the...

Страница 16: ...vision Date Description 1 27 Jul 2006 Original release 2 2 Oct 2006 Updated specifications 3 25 Jan 2007 Added special order specification 4 11 Oct 2007 Updated for new filter updated specifications 5...

Отзывы: