![FTDI FT51A Скачать руководство пользователя страница 97](http://html1.mh-extra.com/html/ftdi/ft51a/ft51a_application-note_2341158097.webp)
Application Note
AN_289 FT51A Programming Guide
Version 1.0
Document Reference No.: FT_000962 Clearance No.: FTDI# 483
96
Copyright © 2015 Future Technology Devices International Limited
2.11.3
Initialization Commands
2.11.3.1
Set Address Enable
Command
: 0xD0
Data
: Write 1 byte
Bit
Symbol
Reset
Description
6..0
Address
0
USB assigned device address. A bus reset will reset all
address bits to 0.
7
Enable
0
Function enable. A bus reset will automatically enable
the function at default address 0.
Table 2.119 Address Enable Register
2.11.3.2
Set Endpoint Enable
Command
: 0xD8
Data
: Write 1 byte
Bit
Symbol
Reset
Description
0
EP_Enable
0
Enable all endpoints (Note EP0 is always enabled
regardless the setting of EP_Enable bit). Endpoints can
only be enabled when the function is enabled.
7..1
Reserved
0
Reserved, write to 0
Table 2.120 Endpoint Enable Register
2.11.3.3
Set Mode
Command
: 0xF3
Data
: Write 2 bytes