FSP EssenSolar CFS model User Manual
www.fsp-group.com.tw
14
03
AC input voltage range
Appliances (default)
If selected, acceptable AC input voltage
range will be within 90-280VAC.
UPS
If selected, acceptable AC input voltage
range will be within 170-280VAC.
05
Battery type
AGM (default)
Flooded
User-Defined
If “User-Defined” is selected, battery charge
voltage and low DC cut-off voltage can be
set up in program 26, 27 and 29.
06
Auto restart when
overload occurs
Restart disable
(default)
Restart enable
07
Auto restart when over
temperature occurs
Restart disable
(default)
Restart enable
09
Output frequency
50Hz (default)
60Hz
10
Output voltage
220V
230V (default)
240V
11
Maximum utility charging
current
Note: If setting value in
program 02 is smaller
than that in program in
11, the inverter will
apply charging current
from program 02 for
utility charger.
2A
10A
20A
30A (default)
40A
50A
60A
12
Setting voltage point
back to utility source
when selecting “SBU
priority” or “Solar first”
in program 01.
Available options in 3kVA model:
22.0V
22.5V