FSM DS01+ Скачать руководство пользователя страница 1

FSM AG | Erich-Rieder-Straße 2 | D-79199 Kirchzarten | [email protected] | www.fsm.ag

27.04.2021

1 | 6

Operating instructions

Pressure transducer | DS01+

Содержание DS01+

Страница 1: ...FSM AG Erich Rieder Straße 2 D 79199 Kirchzarten messtechnik fsm ag www fsm ag 27 04 2021 1 6 Operating instructions Pressure transducer DS01 ...

Страница 2: ... and foreseeable misuse 3 1 4 Functions 3 2 Notes for your safety 3 3 Installation and start up 4 3 1 Scope of delivery 4 3 2 Assembly 4 3 3 Start up 4 3 3 1 Connection 4 3 3 2 Setting the measuring range 4 3 3 3 Setting the output signal 5 3 3 4 Setting the time constant 5 4 Maintenance and service 6 4 1 Zero point correction 6 4 2 Cleaning 6 4 3 Repair 6 5 Accessories and spare parts 6 6 Technic...

Страница 3: ...ed use and foreseeable misuse The DS01 differential pressure transmitter is used to detect low pressures and convert them into a pressure proportional measuring signal The device may only be used in the specified measuring range Only differential pressures of non aggressive gases may be measured with the DS01 Notice Do not use the device in explosive atmospheres or for measurement of aggressive ga...

Страница 4: ...of sources of interference or heat 3 3 Start up 3 3 1 Connection Connect the supply voltage as well as the output wiring according to the connection diagram For this purpose run the cables through the cable glands attached to the housing and connect them to the screw terminals provided In order to guarantee the specified accuracy the sensor should only be fully put into operation after a run in ti...

Страница 5: ...Pa 0 100 hPa Off Off Off 0 75 hPa On Off Off 0 50 hPa Off On Off 0 25 hPa On On Off 100 100 hPa Off Off On 75 75 hPa On Off On 50 50 hPa Off On On 25 25 hPa On On On 3 3 3 Setting the output signal You can adapt the respective desired analog output to your application via the DIP switch S4 The respective setting options can be found in the following table Output signal Position S4 0 10 V 4 20 mA O...

Страница 6: ...s solvents alcohol based cleaners or abrasive cleaners to dampen the cloth Remove soiling of the housing the connectors and the display 4 3 Repair Notice Repairs may only be carried out by the manufacturer or appropriately authorized and qualified personnel If changes are made to the device independently the warranty will expire 5 Accessories and spare parts The scope of accessories may vary depen...

Отзывы: