APPENDIX C – PARADOX SERIAL INTERFACE

The TXC+ can send alarms received from the serial port of the Paradox E65, MG5050 and SP6000 
alarm panels.

Events Sent By the Paradox Alarm Panel
The table below shows the Contact ID codes which will be sent in response to the messages 
received from the Paradox E65/MG5050 and SP6000 alarm panel serial ports.

PARADOX

CONTACT ID

EVENT GROUP NO

SUB-GROUP NO

CONTACT ID 

CODE

EVENT (1)

RESTORE (3)

ZONE/

USER

 

 

 

 

 

06 = Non Reportable Event

00 = Telephone Line Trouble

350

1

0

29 = Arming with User

01 - 32 = User Number

400

3

USER

 

 

 

 

 

30 = Special Arming
 
 

03 = Partial Arming

456

3

0

05 = Arm Keyswitch

409

3

99

06 = Arm Keyswitch

456

3

0

31 = Disarming with User

01-32 = User Number

401

1

USER

32 = Disarming after Alarm with user

01-32 = User Number

401

1

USER

34 = Special Disarming
 

N/A

401

1

USER

05 = Disarming with Keyswitch

401

1

USER

36 = Zone In Alarm

01 to 32 = Zone Number

130

1

ZONE

37 = Fire Alarm

01 to 32 = Zone Number

110

1

ZONE

38 = Zone Alarm Restore

01 to 32 = Zone Number

130

3

ZONE

40 = Special Alarm
 
 
 

00 = Panic non-medical emergency

120

1

0

01 = Panic medical

100

1

0

02 = Panic Fire

110

1

0

05 = Duress Alarm

120

1

0

42 = Zone Tampered

01-32 = Zone Number

380

1

ZONE

 

 

 

 

 

Содержание TX Cellular Plus

Страница 1: ...Tel 0861 105 962 www fsk co za FSK TX CELLULAR PLUS Installation and Programming Guide ...

Страница 2: ...er zone and partition identification in plain text Interfaces 7 Hardwired inputs with positive trip negative trip or both Dedicated AC Supply monitoring input 2 on board relay outputs which can controlled by SMS missed call or via the remote control Optional Relay output expansion board 8 relays per board giving a total of 10 outputs Contact ID Tip and Ring Telephone interface to all leading contr...

Страница 3: ...s The dry contact inputs can be used to detect alarms generated from the outputs of the Alarm Panel or from other sources If the external device generates the alarm by pulling the input to ground negative trigger the pull up jumper should be inserted on the input of the TXC Contact ID Inputs The TXC can intercept signals sent by the alarm panel on its telephone line Contact ID interface If the Con...

Страница 4: ... or SIM 2 The TXC is starting the GSM modem r 1 or 2 Restarting The TXC is re starting the GSM modem c lower case 1 or 2 Connecting The TXC is connecting to the GSM network C upper case 1 or 2 Connected The TXC is connected to the GSM network and is ready to send alarms C S Connecting to server Sending GPRS alarms d S Disconnecting from server All alarms sent disconnecting from the server F 2 Send...

Страница 5: ... that the TXC is not programmed to use the open SIM holder SMS fail The TXC cannot send the SMS Or The network has returned an error in response to the TXC sending the SMS Make sure that the SIM card is capable of sending SMS messages If it is a pay as you go SIM card make sure that it has available funds loaded onto the SIM card Server Connection Fail The TXC cannot connect to the FSK server to r...

Страница 6: ...d The FSK programming cable and RS232 converter is required to program the TXC see Appendix E Handheld Programmer The FSK Handheld Programmer is a programming and diagnostics tool which can be used with the TXC When the TXC is used in conjunction with the handheld Programmer in diagnostics mode any problems connecting to the GSM network can be determined SMS Programming Many of the settings on the...

Страница 7: ...utput 2 on Relay 2 2off Turn output 2 off Relay 2 3on 10on Turn outputs 3 10 on the expansion module on Format is output number 3 10 and output state on off 3off 10off Turn outputs 3 10 on the expansion module off Change the default SIM card to be used for TXC units fitted with two SIM cards Use this command with care as it will stop the TXC from functioning if a SIM card is selected which is not ...

Страница 8: ... 1 send 1 Phonenumber where Phonenumber is the cell phone number To retrieve the value send the KEYWORD followed by no space e g 1 to request the phone number Note when requesting the phone number the TXC will respond with all the stored phone numbers KEYWORD DESCRIPTION TO CHANGE 0 Unit description 0 Name 1 Phone number 1 1 Phonenumber 2 Phone number 2 2 Phonenumber 3 Phone number 3 3 Phonenumber...

Страница 9: ... KEYWORD DESCRIPTION 256 AC OK AC Restored SMS Text 257 Battery OK SMS Text 322 AC Failed SMS Text 323 Battery low SMS Text 258 Input 1 High SMS Text 259 Input 2 High SMS Text 260 Input 3 High SMS Text 261 Input 4 High SMS Text 262 Input 5 High SMS Text 263 Input 6 High SMS Text 264 Input 7 High SMS Text 324 Input 1 Low SMS Text 325 Input 2 Low SMS Text 326 Input 3 Low SMS Text 327 Input 4 Low SMS...

Страница 10: ...tton 4 SMS Text 395 Remote Control Button 5 SMS Text 397 Remote Control Button 6 SMS Text 398 Missed Call SMS text APPENDIX B TEXECOM SERIAL INTERFACE The TXC can receive alarms from the Texecom Premier range of alarm panels Using a modem connected to a computer the TXC can also be used to remotely upload and download the Texecom premier alarm panels TXC to Texecom Premier Serial Interface Cable ...

Страница 11: ...g the Texecom Premier Alarm Panel The Texecom premier alarm panel can be uploaded and downloaded using the Texecom WinTex software available at www texe com Please contact the local Texecom agent for more details A PC based modem for is available from FSK Electronics which can be used to connect to the Alarm Panel via the TXC The Wintex Software requires the IP Address and Port Number of the TXC t...

Страница 12: ...12 When connecting to the Texecom panel through the TXC select the connection option of CONNECT VIA NETWORK from the Wintex Software SELECT CONNECT VIA NETWORK ...

Страница 13: ...ine Trouble 350 1 0 29 Arming with User 01 32 User Number 400 3 USER 30 Special Arming 03 Partial Arming 456 3 0 05 Arm Keyswitch 409 3 99 06 Arm Keyswitch 456 3 0 31 Disarming with User 01 32 User Number 401 1 USER 32 Disarming after Alarm with user 01 32 User Number 401 1 USER 34 Special Disarming N A 401 1 USER 05 Disarming with Keyswitch 401 1 USER 36 Zone In Alarm 01 to 32 Zone Number 130 1 Z...

Страница 14: ...l Current Overload Rest 320 3 0 46 Bus wireless module new trouble 01 tamper Trouble 137 1 0 48 Special Partition 1 only 01 Reporting Test 602 1 0 04 Installer Entered Prog Mode 627 3 0 05 Installer Exited Prog Mode 628 1 0 07 Maintenance Exited Prog Mode 49 Low Battery on Zone 01 32 Zone Number 302 1 ZONE 50 Low Battery on Zone Restore 01 32 Zone Number 302 3 ZONE 51 Zone supervision trouble 01 3...

Страница 15: ...15 APPENDIX D PIMA SERIAL INTERFACE The Pima serial interface will send the standard FSK Contact ID alarm codes ...

Страница 16: ...16 APPENDIX E PROGRAMMING CABLE TOPS 0861 10 22 10 JB10812 ...

Отзывы: