6. OPERATING PRINCIPLES
The pump draws fuel from the tank and brings it to the operating pressure. The fuel is brought to the nozzle that sprays it into the
combustion chamber. The combustion is carried out with a mix of air and fuel and flow of air generated is pushed outside via the
rotation of the fan. In indirect models combustion products are directed outside through the chimney. A series of sensors connected
to an electronic control board constantly keep the correct operation of the heater monitored and stops the cycle in the event of
anomalies.
7. OPERATION
7.1 SWITCHING ON THE HEATER:
7.1.1. Please follow the safety instructions.
7.1.2. Check if there is enough fuel in the tank.
7.1.3. Close the tank cup (pic. 1)
7.1.4. Plug in supply cord to 115V minimum 15 Amp outlet (pic. 2) (SEE VOLTAGE IN THE “TECHNICAL DATA TABLE”).
7.1.5. Set the “I/O” switch to “I” (pic. 3). The heater should turn on within a few seconds. If the heater does not start, refer to
paragraph “12. TROUBLESHOOTING”.
7.1.6. For models with a room thermostat, check the positon of the knob (pic. 4)
PLEASE NOTE: IF THE HEATER SWITCHES OFF DUE TO LACK OF FUEL, TOP UP THE TANK AND RESET THE HEATER
(SEE PAR. 7.2).
7.2. RESETTING THE HEATER:
The appliance stops when an anomaly occurs. The reset button turns on with a steady red light (pic. 5), it means the heater needs
to be reset. To reset the heater, press the reset button all the way down (pic 6). Identify and remove the cause that stopped the
appliance (for instance, obstruction of air intake and/or outlet, total block of the fan, etc.). Please contact an appointed service
center for assistance in case it is impossible to solve the problem.
7.3. SWITCHING OFF THE HEATER:
Set the “I/O” button to “0” (pic 7). Flames extinguish and the fan keeps o working until the combustion chamber
has fully cooled down.
Do not pull the plug out until the cooling cycle has totally ended.
8. CLEANING THE FILTERS
THE FILTERS MAY NEED TO BE CLEANED DEPENDING ON THE QUALITY OF THE FUEL USED.
A.
Combustion chamber and burner,
B.
Fan,
C.
Motor,
D.
Pump,
E.
Tank,
F.
Chimney
WARNING: Carefully read the “SAFETY
INFORMATION” before switching on the
heater.
WARNING: Exhaust gas pipe connection
must be installed following the installation
instruction on the end of this manual. The
chimney should have a minimum of 0.04”
W.C. draft to ensure safe operation of the
unit. The heater is according to CSA
B140.8
-
8.3.4.2. The vent outlet on the
heater is 6” diameter. Certified venting
system must be used at all times. All
venting must correspond with local codes.
Vent cap should be installed in situations
where downdrafts occur.
IMPORTANT: In indirect models,
combustion products are directed outside
through suitable chimney. CARRY OUT
THE CHIMNEY IN ACCORDANCE WITH
CURRENT SAFETY REGULATIONS AND
FOLLOW THE INSTRUCTIONS IN THE
RELEVANT SECTION OF THE MANUAL.