1.

 

DESCRIPTION

 

This series of indirect heaters is particularly suited to 

heating medium to large

-

sized rooms or areas. Thanks 

to a heat exchanger, indirect heaters separate       

combustion gases from the hot air released into the 

environment. This way it is possible to introduce a flow 

of clean hot air in the area that needs to be heated up 

and direct exhaust fumes outside. 

 

These heaters have been designed in line with the 

most recent safety, operating and duration criteria. The 

safety devices ensure the machine always operates 

correctly

 

     

 

          

IMPORTANT: 

This appliance is not suitable for use by persons (including children) 

with reduced physical, sensory and mental capacities or with lack of experience or knowledge 

unless supervised by a person responsible for their safety. Children must be supervised to make 

sure they do not play with the appliance. 

 

 

          

DANGER: 

Suffocation by carbon monoxide can be fatal.

 

 

          

IMPORTANT: 

The installation of this heater for use with No. 1, No. 2, Diesel or       

Kerosene and shall conform with local codes. 

 

 

          

IMPORTANT: 

THE INSTALLATION OF THE UNIT SHALL BE IN ACCORDANCE WITH 

THE REGULATIONS OF THE AUTHORITIES HAVING JURISDICTION. 

 

2. SAFETY INFORMATION

 

WARNINGS

 

The first symptoms of suffocation by carbon monoxide are similar to those of flue with headache, 

light

-

headedness and/or nausea. These symptoms could be caused by the faulty functioning of 

the heater. IF THESE SYPTOMS OCCUR, GO OUTDOORS IMMEDIATELY and have the heater 

repaired by a technical service center.

 

Содержание F-HVF1101

Страница 1: ... Lake Ohio 44054 Phone 440 949 2400 Fax 440 949 2900 Email sales fsinorth com Visit us on the web at www fsinorth com 03 16 PORTABLE AIR HEATERS MANUAL FSI OIL INDIRECT FIRED AIR HEATER MODELS F HVF1101 F HVF2101 F HVF3101 ...

Страница 2: ...N MONOXIDE A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM WARNING NOT FOR HOME OR RECREATIONAL VEHICLE USE We cannot anticipate every use which may be made for our heaters CHECK WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE QUESTIONS ABOUT LOCAL REGULATIONS Other standards govern the use of fuel gases and heat producing products in spec...

Страница 3: ... FUEL OIL 17 GAL 17 GAL 27 7 GAL 120 V 15 10 60 HZ 7 5 A 0 9 KW 120 V 15 10 60 HZ 7 5 A 0 9 KW 120 V 15 10 60 HZ 11 4 A 1 4 KW 135 LB 148 LB 271 LB NOZZLE 0 65 US GPH 80 S DANFOSS 1 00 US GPH 80 S DANFOSS 1 50 GPH 80 S DANFOSS PRESSURE 174 PSI 12300 KPA 12 BAR 145 PSI 1000KPA 10 BAR 174 PSI 1200KPA 12 BAR CERT TECHNICAL DATA IMPORTANT In order to have a correct function you must use an electrical ...

Страница 4: ... criteria The safety devices ensure the machine always operates correctly IMPORTANT This appliance is not suitable for use by persons including children with reduced physical sensory and mental capacities or with lack of experience or knowledge unless supervised by a person responsible for their safety Children must be supervised to make sure they do not play with the appliance DANGER Suffocation ...

Страница 5: ...5v supply must be available Please note that the heater requires minimum 15 amps for proper operation Ensure appropriate gauge extension cord is used 12 3 AWG at 50 Ft 10 3 AWG at 100 Ft 2 2 7 The recommended safety distances between heaters and flammable substances are front output 5 ft side top output 2 ft 2 2 8 Avoid fire hazards by placing the hot or functioning heater on a flat level surface ...

Страница 6: ...et button turns on with a steady red light pic 5 it means the heater needs to be reset To reset the heater press the reset button all the way down pic 6 Identify and remove the cause that stopped the appliance for instance obstruction of air intake and or outlet total block of the fan etc Please contact an appointed service center for assistance in case it is impossible to solve the problem 7 3 SW...

Страница 7: ...8 4 FUEL PUMP FILTER See the preventive maintenance schedule 9 STORAGE AND TRANSPORT IN ORDER TO KEEP THE HEATER IN THE BEST POSSIBLE CONDITIONS WE RECOMMEND TO FOLLOW THE BELOW PROCEDURE 9 1 Empty the fuel by removing the drain cap at the bottom of the tank pic 5 Dispose of the fuel in an appropriate container in accordance with the current safety regulations 9 2 To remove any residual remaining ...

Страница 8: ...he working environment temperature pic 4 6 Top off fuel and reset heater 7a Empty rinse and refill the tank 7b Rinse the filters SEE PAR 8 7c Contact a service center Smoke while operating 1 External substances or dirt in the fuel circuit 2 Obstructed inlet air vent 1a Empty and refill the tank with clean fuel 1b Rinse fuel filters 1c Contact a service center 2 Remove all air vent obstructions The...