Oil-Free Scroll Compressor 4kW ~ 15kW
Fault description
Causes
Remedy
Personnel
Blocked pipeline
Check or change pipeline
Trained staff
safety valve open
Check valve malfunction Check or change check valve
Manufacturer
Abnormal
pressure
sensor line
Check or change pressure sensor line Trained staff
Time for spare
time
Abnormal
control
cabinet line
Check or change control cabinet line
Manufacturer
Unable to build
pressure
Excessively high air
inflow or ambient tem-
perature
Improve ventilation of air compressor
room
Manufacturer
Abnormal machine body Check or change machine body
Qualified
electrician
Voltage below level
Adjust main power
Manufacturer
Pipeline leakage
Check air compressor and system
pipeline for leakage
Manufacturer
Abnormal check valve
Check or change check valve
Manufacturer
Abnormal
pressure
value set
Check pressure value set for security
valve
Trained staff
Abnormal sound
Air compressor reverse
rotating
Check or place piping
Qualified
electrician
Abnormal airend
Check or change airend
Manufacturer
Abnormal belt
Check or change line
Trained staff
Abnormal motor
Check or change pipeline
Manufacturer
8.4 Trial run after troubleshooting
Please do as follows to carry out trail run after
troubleshooting:
1.
Reset emergency button.
2.
Confirm malfunction record,
Controller
Instruction Manual.
3.
All staffs are evacuated from the danger
area.
4.
Startup the oil-free scroll compressor
Con-
troller Instruction Manual.