Oil-Free Scroll Compressor 4kW ~ 15kW
-
Standard air compressor exhaust
temperature is ambient tempera-
ture + 180
℃
.
-
Standard exhaust temperature
shall not be higher than 220 de-
grees C, if more than this temper-
ature, the operating panel will ap-
pear warning messages and air
compressor will stop.
1.
Check compressor temperature.
7.4.4
Checking soiling of th cooler
Personnel:
◼
Qualified personnel
Protective
equipment:
◼
Safety boots
◼
Protective work clothing
◼
Light respiratory
protection
◼
Safety goggles
◼
Protective gloves
1.
Switch the oil-free scroll compressor off and
secure to prevent restarting.
2.
Open and remove the upper covers of sound
insulation with the special spanner.
3.
Check compressed air and coolant liquid cool-
er from inside and outside for soiling.
4.
Remove soiling.
Soiling can be removed by blow-
ing it out, e.g. While doing this,
make sure that the soiling from the
device is blown out of rather than
into the machine. In case of
severe soiling, consult the
manufacturer.
7.4.5
Checking main motor
Personnel:
◼
Qualified personnel
Protective
equipment:
◼
Safety boots
◼
Protective work clothing
◼
Light respiratory
protection
◼
Safety goggles
◼
Protective gloves
1.
Switch the oil-free scroll compressor off and
secure to prevent restarting.
2.
Open and remove the sound insulation covers
with the special spanner.
3.
Visually check of main motor.
In case of visible defects, contact the man-
ufacturer.
7.4.6
Add lubricating grease for main
motor bearing
Personnel:
◼
Qualified personnel
Protective
equipment:
◼
Safety boots
◼
Protective work clothing
◼
Light respiratory
protection
◼
Safety goggles
◼
Protective gloves
Materials:
◼
Lubricating
grease
f there is no lubricating grease inlet
in the main motor, the main motor is
filled with permanent lubricating
grease.
1.
Switch the oil-free scroll compressor off.
2.
Open and remove the sound insulation covers
with the special spanner.
3.
For quantity of lubricating oil required for
motor bearing, please see information on the
motor label.
Lubricating grease inlets all locate
at rear sides of main motor.
Содержание ECO Series