Troubleshooting 

Problem 

Possible Cause(s) 

Solution 

Leaking from 
Chamber 

1. O-Rings Not Seated 
 
 
2. Knurled Nut Too Loose 
 
 
 
 
3. Damaged Thimble 
 
 
 
 
 
 

1.

 If there is any issue with the o-ring in the way they 

are seated this will need to be fixed. Remove the 
thimble and repeat steps 3 

– 5. 

2.

 If the nut is not tight enough, the O-rings will not 

have good enough compression and will cause a 
leak. Slightly tighten up the nut until a watertight seal 
is achieved. It is better to tighten slightly at a time to 
prevent overtightening.  

3.

 If there is a crack or hole in the thimble, it will fill 

from the inside out. Turn off the water, disconnect 
the power, carefully remove the thimble and replace 
with a new one. If the thimble releases shards of 
glass, the chamber and downstream plumbing will 
need to be thoroughly checked. All glass shards 
must be removed before re-connection. 

High Water 
Temperature 

1. Low Flow Rate 
 
 
 
 
 
 
 
 
2. Oversized System 

1.

 Particularly on the smaller model (GT7-2K), if 

there are periods of low water usage or the water is 
allowed to stand for long periods of time, the water 
may be prone to heating up and may be either 
lukewarm or hot. Generally, this only occurs on 
systems that have a short distance between the 
outlet and point of use. Whole house systems have 
a larger length of cold plumbing pipes downstream 
which will dissipate this heat. 

2.

 If the system is too large for the application, it is 

likely that even with frequent water usage, the water 
does not get a chance to cool down effectively. If 
there are significant fluctuations in usage or flow 
rates, it is good practice to install a thermal relief 
valve (sold separately) on the outlet of the UV 
chamber which can bleed water from the chamber 
and keep temperatures below 56°C. 

Hot SS Chamber 

1. Low Usage 

1.

 As above, if the water is allowed to stand for 

periods of time, the chamber will heat up naturally. 
This is normal, however if the heating is excessive to 
the point where it is causing damage to the chamber 
or surrounding fixtures, a thermal relief valve (sold 
separately) should be installed on the outlet of the 
UV chamber, to bleed water from the chamber and 
keep temperatures below 56°C. 

Ballast is Alarming 

1. Lamp Failure 
 
 
 
 
 
 
 
 
 
 
 
 
2. False Alarm 

1.

 Usually if the ballast is alarming and showing a 

red flashing status indicating light, the lamp has 
failed and will require replacement. Before replacing 
a lamp, it is best to check firstly for an external 
cause for lamp failure turn off the power then check 
for; Water ingress from either rain, or leaks or any 
signs of moisture or condensation in/around the 
electricals. Due to the elevated temperature of the 
lamp, high humidity may cause condensate to form. 
If there are no signs of leaking, check for signs of 
shorts or charring on the lamp connection with the 
ballast. Lastly inspect the tube to see if there are any 
dark patches or if the filaments are burnt out.  

2.

 Sometimes the ballast may trigger a failure alarm 

if the connection to the lamp is interrupted or 
perhaps the connection is not solid enough. If the 
above steps reveal no faults and the lamp is still 
working (lighting up), turn the power off for 5 

Содержание GT7- 16K

Страница 1: ...ements 3 VI What is Ultraviolet Sanitation 3 VII Example Applications 3 Installation Introduction 4 I Site Preparation 4 II Mounting 4 III Installing Connections 4 IV Thermal Relief Valve 4 V Filter P...

Страница 2: ...must be followed closely to prevent serious personal injury Ensure eye protection is worn when servicing and installing this unit to protect from harmful UV C Radiation This radiation can be harmful...

Страница 3: ...ounding plumbing must be earthed to prevent electrolysis which will cause corrosion VI What is Ultraviolet Sanitation Ultraviolet sanitation works by breaking down the cell wall of a micro organism al...

Страница 4: ...to install a TRV to limit the temperature When installing a TRV note the below requirements The TRV must be installed on the Outlet of the UV System which should be the open end The TRV tube must be a...

Страница 5: ...last Operation GT7 8K PS The 10W 40W ballast is straightforward for operation It features a lamp status failure indicator light along with an audible alarm should there be a fault The ballast will aut...

Страница 6: ...ow the lamp to fire Do not look directly at the lamp without eye protection c Confirm that the lamp lights up correctly and the ballast is showing a green light to signify that the lamp is running cor...

Страница 7: ...ough Thus we recommend replacing the lamp every 12 months and the thimble every 1 2 years Lamp Replacement Every 12 Months GT7 2K Lamp 14W Replacement UV Lamp Suit GT7 2K GT7 4K Lamp 20W Replacement U...

Страница 8: ...et a chance to cool down effectively If there are significant fluctuations in usage or flow rates it is good practice to install a thermal relief valve sold separately on the outlet of the UV chamber...

Страница 9: ...arranty period please contact the manufacturer for further instructions 2 Check the wall socket with a different electrical appliance to check if the GPO is functioning Also check your circuit breaker...

Страница 10: ...plumber The consumer is responsible for keeping record and proof of installation in the form of an invoice and or receipt Filter systems must be maintained as per FSA recommendations including the us...

Страница 11: ...warranty is subject to terms and conditions outlined below This extended warranty covers the below parts of the system Ultraviolet Chamber 316 Stainless Steel Extended Warranty Qualification Extended...

Отзывы: