Ultraviolet systems are rated based on a dosage level of UV-C radiation into the water (mJ/cm²), with 
30mJ/cm² being the standard level of disinfection and a minimum dose of 40mJ/cm² required to comply 
with Australian Drinking Water Guidelines. Ultraviolet Lamps are rated with a 9000-hour (1 year) lifespan, 
after which point the lamp will naturally degrade and the level of radiation produced by the lamp cannot be 
guaranteed. They are designed for continuous run, not for intermittent operation. 

The UV lamp sits inside a quartz thimble, which protects the electrical components of the lamp from making 
contact with the water. We specifically use quartz (fused silica) for this application because it is strong, 
exhibits thermal resistance, and has excellent UV transmission properties. However, over time, metal ions 
fused within the silica structure of the quartz thimble interfere with the UV-C radiation produced by the 
lamp, which reduces the UV transparency of the glass and causes it to become fragile. This process is 
called solarization. 

Tannin, bio-film, algae, and scale can also build up on the outside of the glass thimble, further preventing 
ultraviolet light produced by the lamp from penetrating through the thimble, and impairing the system's 
ability to sanitise the water passing through. 

Thus, we recommend replacing the lamp every 12 months, and the thimble every 1-2 years. 

Lamp Replacement | Every 12 Months

 

GT7-2K-Lamp  

 

14W Replacement UV Lamp Suit GT7-2K 

GT7-4K-Lamp  

 

20W Replacement UV Lamp Suit GT7-4K 

GT7-8K-Lamp  

 

40W Replacement UV Lamp Suit GT7-8K 

GT7-9K-Lamp  

 

40W Replacement UV Lamp Suit GT7-9K 

GT7-16K-Lamp 

 

87W HO Replacement UV Lamp Suit GT7-16K 

Quartz Thimble Replacement | Every 1 

– 2 years depending on water quality 

GT7-2K-Thimble 

 

331mm x 23mm OD Single Open-End Thimble Suit GT7-2K 

GT7-4K-Thimble 

 

490mm x 23mm OD Single Open-End Thimble Suit GT7-4K 

GT7-8K-Thimble 

 

895mm x 24.5mm OD Single Open-End Thimble Suit GT7-8K 

GT7-9K-Thimble 

 

895mm x 23mm OD Single Open-End Thimble Suit GT7-9K 

GT7-16K-Thimble 

 

895mm x 23mm OD Single Open-End Thimble Suit GT7-16K 

O-Tings | Every 1 

– 2 Years, must be changed if installing a new quartz 

GT7-2NSF-OR 

 

O-Ring Suit 23mm Thimble (GT7-2K, GT7-4K, GT7-8K & GT7-16K) 

GT7-8NSF-OR 

 

O-Ring Suit 24.5mm Thimble (GT7-8K ) 

Replacement Ballast | Replace after 5 years as a precaution 

GT7-8K-PS 

 

 

10W 

– 40W AU Certified (RCM) Ballast to Suit 4 Pin Lamps 

GT7-16K-PS   

 

33W 

– 120W AU Certified (RCM) Ballast to Suit 4 Pin Lamps 

Mounting Clamps 

GT11-8G 

 

 

1 PC Plastic Mounting Clamp Suitable for U/Sink Installation.

 

GT7-8-BRK 

 

 

1 Pair Aluminium Mounting Brackets Suit GT7-4K GT7-8K GT7-9K GT7-16K 

Thermal Relief Valves 

GT7-53 

 

 

¾” F-F BSP Thermal Relief Valve – 316SS + 2m Drain Tubing 

GT7-51 

 

 

1” F-F BSP Thermal Relief Valve – 316SS + 2m Drain Tubing 

GT7-52 

 

 

2” F-F BSP Thermal Relief Valve – 316SS + 2m Drain Tubing 

 

Содержание GT7- 16K

Страница 1: ...ements 3 VI What is Ultraviolet Sanitation 3 VII Example Applications 3 Installation Introduction 4 I Site Preparation 4 II Mounting 4 III Installing Connections 4 IV Thermal Relief Valve 4 V Filter P...

Страница 2: ...must be followed closely to prevent serious personal injury Ensure eye protection is worn when servicing and installing this unit to protect from harmful UV C Radiation This radiation can be harmful...

Страница 3: ...ounding plumbing must be earthed to prevent electrolysis which will cause corrosion VI What is Ultraviolet Sanitation Ultraviolet sanitation works by breaking down the cell wall of a micro organism al...

Страница 4: ...to install a TRV to limit the temperature When installing a TRV note the below requirements The TRV must be installed on the Outlet of the UV System which should be the open end The TRV tube must be a...

Страница 5: ...last Operation GT7 8K PS The 10W 40W ballast is straightforward for operation It features a lamp status failure indicator light along with an audible alarm should there be a fault The ballast will aut...

Страница 6: ...ow the lamp to fire Do not look directly at the lamp without eye protection c Confirm that the lamp lights up correctly and the ballast is showing a green light to signify that the lamp is running cor...

Страница 7: ...ough Thus we recommend replacing the lamp every 12 months and the thimble every 1 2 years Lamp Replacement Every 12 Months GT7 2K Lamp 14W Replacement UV Lamp Suit GT7 2K GT7 4K Lamp 20W Replacement U...

Страница 8: ...et a chance to cool down effectively If there are significant fluctuations in usage or flow rates it is good practice to install a thermal relief valve sold separately on the outlet of the UV chamber...

Страница 9: ...arranty period please contact the manufacturer for further instructions 2 Check the wall socket with a different electrical appliance to check if the GPO is functioning Also check your circuit breaker...

Страница 10: ...plumber The consumer is responsible for keeping record and proof of installation in the form of an invoice and or receipt Filter systems must be maintained as per FSA recommendations including the us...

Страница 11: ...warranty is subject to terms and conditions outlined below This extended warranty covers the below parts of the system Ultraviolet Chamber 316 Stainless Steel Extended Warranty Qualification Extended...

Отзывы: