VI. Assembling the System 

The System is supplied pre-made and assembled so there is nothing needing to be done before 
commencing the installation. The Membrane is loaded into the housing already. 

Connecting the RO System 

I. Tubing 

Measure a length of white tubing (Inlet Tubing) to be installed between the FWA and the ‘Inlet’ port on the 
filter system. The Pressure Limiting Valve will be installed on this line. Cut using a sharp Box Cutter knife or 
tube cutters. When connecting to the system refer to the ‘Quick Connect Fitting’ Instructions. To connect to 
the FWA, unscrew the lock nut until it hits a stop end. Push the tubing in firmly until you feel it ‘seat’. Finally, 
tighten the locking nut to secure the tubing – this will prevent the tubing from releasing. 

Measure a length of tubing to go between the Storage Tank & the Tank Tee fitting located on the final stage 
filter. 
Measure a length of tubing to go between the Drain clamp & the Flow Restrictor (Labelled Drain Line). 
Measure a length of tubing to go between the Faucet & the Final Stage filter (Inline Fluid Reactor) 

System Start Up & Operation 

I. Plumber Commissioning Steps 

When you are confident that the system is correctly installed, do the following steps to start up the system 
and commence the flushing procedure. 

1.  Open the faucet tap – This helps bleed air from the system when you introduce the feed water. 
2.  Close the Storage tank valve – we want the system & filters to be totally wetted down and full to 

allow the air to escape. 

3.  Smoothly open the FWV allowing water to enter the system, it is common to hear and see sputtering 

as the water makes its way through the system forcing out the air. 

NOTE: Check for any leaks, if there are leaks, shut off the water, fix them and continue.

 

4.  It will take a few minutes for the water to make its way out the faucet due to the low flow rate of the 

membrane. The drain line however should begin to run as soon as water reaches the membrane. 

5.  When the water first comes out of the tap, it will be grey and discoloured – this is normal as the 

carbon fines are flushed out of the dry filters.  

NOTE: Air bubbles are also common in the water – it gives the water a ‘milky’ appearance. 
This will eventually dissipate as the air is flushed from the system – this can sometimes take 
a few days to stop completely. The water is still safe to drink.

 

6.  Once the faucet comes to a steady trickle of water and stops sputtering, close the faucet tap. This 

should trigger the systems automatic shut off within 1 minute (Water should stop flowing). If the 
water does not shut off within 60 seconds, it could be due to an air lock in the shut off valve which is 
common for new installs. 

7.  Open the tank valve so the tank can begin filling. The tank will take up to 2 hours to fill depending 

on several factors. 

II. Client can Complete Commissioning 

Note for Plumbers: At this point, if you are confident that the system is functioning correctly and 
there are no signs of leaks or any concerns, you can finish your portion of the installation at this 
point – ensure that the client is aware of the following steps to conduct next. We suggest that you 
(As the plumber) understand the remaining portion of the manual in case the client has further 
questions or to help basic troubleshooting.

  

8.  When the tank has had long enough to fill, open the faucet tap on the sink and allow all the stored 

water to flush out the system. You should notice some discolouration/cloudiness which is normal. 
Repeat this process at 

least

 2 times to clear the fines from the system.  

The RO membrane has a small amount of food grade anti-bacterial preserve inside it which will be 
flushed out during these flushes. Air bubbles are common to remain in the system for up to 2 weeks 
but they will disappear quicker if the system is flushed more or used frequently. 

Содержание GT1-70

Страница 1: ...ter Connection 3 II Drain Clamp 3 III Drilling Faucet Hole Stainless Steel Sink 3 IV Mounting the Faucet 4 V Storage Tank Assembly 4 VI Assembling the System 5 Connecting the RO System 5 I Tubing 5 Sy...

Страница 2: ...ssure 175 kPa 700 kPa Temperature 4 5 C 38 C pH Level 2 11 TDS 0 mg L 2 000 mg L Iron 0 mg L 0 3 mg L Manganese 0 mg L 0 1 mg L Hardness 0 mg L 200 mg L III Space Requirements System Dimensions Height...

Страница 3: ...tween DO NOT apply thread tape to these connections as they are designed to use the washers only Thread tape is only required on the male thread of the FWA if it is not installing to a flex line With...

Страница 4: ...tance thread the Compression nut over the tubing followed by the cone washer Then firmly press the gasket into the end of the tubing You can then insert the tubing into the base of the faucet and secu...

Страница 5: ...t the faucet due to the low flow rate of the membrane The drain line however should begin to run as soon as water reaches the membrane 5 When the water first comes out of the tap it will be grey and d...

Страница 6: ...e first 45 seconds of water If the system has been shut down for over 1 week discard a full tank of water Maintenance I Replacement Parts Filtration tubing should be replaced periodically about every...

Страница 7: ...Water Quality 1 Turn on the water supply and ensure there are no obstructions to the water flow 2 Disconnect the tube between the membrane and pre filters and run water at full pressure to see if wate...

Страница 8: ...of the water especially when new If you have low TDS water already it is possible for the TDS level out of the alkaline filter to be higher than your inlet water This is because you are adding mineral...

Страница 9: ...suddenly stopped or forced in other directions by fast closing valves Sioux Chief shock arresters are best used at the point of shock and should be installed as close to the valve or piping where the...

Страница 10: ...stems must be installed by a qualified plumber The consumer is responsible for keeping record and proof of installation in the form of an invoice and or receipt Filter systems must be maintained as pe...

Страница 11: ...to terms and conditions outlined below This extended warranty covers the below parts of the system GT8 0S Twin O Ring Housings GT8 31 Reverse Osmosis Housing GT35 12 NPT Stainless Steel Centre Joiner...

Отзывы: