background image

VI. Assembling the System (Photos Below) 

1.  Disconnect tubing from the membrane 

housing cap, unscrew the cap and 
check the o-rings to ensure they are it 
working order. 
 
 
 
 
 
 

2.  Unwrap the Reverse Osmosis 

Membrane and install it into the 
membrane housing, ensure that you 
only handle the membrane by the 
end stems as shown. The 
membrane is inserted firmly o-rings 
first. Replace the membrane cap – 
be careful to keep the o-rings lined 
up correctly to avoid pinching them if 
they fall out while tightening. 
 

3.  Firmly hand tightening the cap is usually sufficient, the opening 

handle membrane attachment can help nip up the housing further if 
required. 
 
 
 
 
 

4.  Unscrew the vertical pre filter housings and unwrap the internal 

cartridges – maintain minimal contact with the surface of the carbon 
filter, handle by the end caps only to avoid contamination 
 
 
 
 
 
 

5.  Screw up the housings while they are in a vertical position to ensure 

the cartridges remain cantered until you begin to feel resistance. (if 
you gently shake the housing you should not be able to feel/hear the 
cartridge rattle inside. Hand tightening these housings is generally 
enough to seal them due to the dual tapered o-ring seal of the 
housings. Only use the opening spanner if the housings need to be 
tightened further to avoid leaks. DO NOT over tighten the housings 
– doing so causes stress on the caps and may cause a split or crack 
causing potential flooding. 
NOTE: The rim of the housing and the cap should not be touching – 
this is too tight. The gap should be approx. 3 mm – 4 mm between 
the cap and the rim of the housing. 

 

You are now ready to connect the system. 

 

Содержание GT1-26-4

Страница 1: ...3 II Drain Clamp 3 III Drilling Faucet Hole Stainless Steel Sink 3 IV Mounting the Faucet 4 V Storage Tank Assembly 4 VI Assembling the System Photos Below 5 Connecting the RO System 6 I Tubing 6 Sys...

Страница 2: ...350 kPa 700 kPa Temperature 4 5 C 38 C pH Level 2 11 TDS 0 mg L 2 000 mg L Iron 0 mg L 0 3 mg L Manganese 0 mg L 0 1 mg L Hardness 0 mg L 200 mg L III Space Requirements System Dimensions 4 Stage Hei...

Страница 3: ...tween DO NOT apply thread tape to these connections as they are designed to use the washers only Thread tape is only required on the male thread of the FWA if it is not installing to a flex line With...

Страница 4: ...tance thread the Compression nut over the tubing followed by the cone washer Then firmly press the gasket into the end of the tubing You can then insert the tubing into the base of the faucet and secu...

Страница 5: ...al cartridges maintain minimal contact with the surface of the carbon filter handle by the end caps only to avoid contamination 5 Screw up the housings while they are in a vertical position to ensure...

Страница 6: ...he water it gives the water a milky appearance This will eventually dissipate as the air is flushed from the system this can sometimes take a few days to stop completely The water is still safe to dri...

Страница 7: ...ing the Pressure Limiting Valve every 2 years If the system is having issues with the shut off valve and is over 2 years old the 4 way shut off valve should also be replaced II Replacement Cartridges...

Страница 8: ...e changed 3 Reverse Osmosis required 50psi Minimum to operate 70psi is ideal If you have lower than 50psi pressure this unit may not be suitable for you 4 Ensure that the water quality meets the feed...

Страница 9: ...mmendations it is likely that the increased TDS is due to the filters needing replacing 4 This is common as sometimes the lines may be mixed up Make sure that the tubing connected to the Drain Line fl...

Страница 10: ...of shock and should be installed as close to the valve or piping where the shock originates from Sioux Chief shock arresters are designed with the latest diaphragm technology A high grade diaphragm i...

Страница 11: ...stems must be installed by a qualified plumber The consumer is responsible for keeping record and proof of installation in the form of an invoice and or receipt Filter systems must be maintained as pe...

Страница 12: ...to terms and conditions outlined below This extended warranty covers the below parts of the system GT8 0S Twin O Ring Housings GT8 31 Reverse Osmosis Housing GT35 12 NPT Stainless Steel Centre Joiner...