M6500 Series NE Configuration Manual
47
Figure4-6 Board Information Interface
4.4. Port Configuration
Select NE-Slot1 click on“
Port1
”, and then select“
Port Management
”on the right
,
as shown in the figure below:
Figure4-7 View Port Configuration Information
4.4.1. Basic Information
There are two port types: client side port and line side (system side) port.
Client side port type supports: FE, GE, 10GE, 40GE, and 100GE, STM-1/4/16, OC-3/12/48, STM-64, OC-192 and
OTU2 (2e)/OTU3/OTU4.
For line side (system side) port type, the grey light supports OTU2/2e and OTU4, and the color light supports
OCh (OTU2/2e) and OCh (OTU4).
Select NE-Slot 1, click on“
Port1
”, and select“
Port Management
”on the right, the interface as shown in the figure
below pops up. The configuration status and port mode can be modified in basic information.
Содержание M6500 Series
Страница 12: ...M6500 Series NE Configuration Manual 11 Figure 1 3 Start NMS Server...
Страница 63: ...M6500 Series NE Configuration Manual 62 Figure 4 34 Parameter Reading of WDM CFP2 Optical Transceiver...
Страница 105: ...M6500 Series NE Configuration Manual 104 Figure5 80 Site to Site Primary and Standby Protection Environment...
Страница 109: ...M6500 Series NE Configuration Manual 108 Figure6 5 TP Multiplexing Configuration Step 2...
Страница 113: ...M6500 Series NE Configuration Manual 112 Figure6 12 Set Line Side PM Overhead...
Страница 116: ...M6500 Series NE Configuration Manual 115 Figure6 16 Configure Line Side Port TTI...
Страница 117: ...M6500 Series NE Configuration Manual 116 Figure6 17 Configure Client Side Local End Port TTI...
Страница 118: ...M6500 Series NE Configuration Manual 117 Figure6 18 Configure Client Side Opposite End Port TTI...
Страница 129: ...M6500 Series NE Configuration Manual 128 Figure7 10 Select Protection Mode...
Страница 138: ...M6500 Series NE Configuration Manual 137 Figure8 14 Alarm Details Figure8 15 Alarm Document Link...