4. Click on“
Apply
”to save the configuration.
Figure2-24 NE Time configuration
2.9. Configure NE Data
Configure NE Data:
Save NE Configuration: In the case of configuring the network element, in order to prevent the
network element from abnormal restarting, the network element configuration is saved
regularly. At present, the configuration data of the network element is automatically saved once
per minute.
Upload NE Configuration: In order to avoid data loss caused by abnormal operation, it needs to
upload the NE configuration to local NMS server regularly.
Download NE Configuration: In order to avoid the loss or modification of the original
configuration caused by the abnormal operation of the network element by the engineer, the
previous configuration is downloaded from the local NMS server to the network element. After it
is successfully downloaded, the network element will be restarted automatically. After the
restart, the configuration will be automatically saved on the network element.
To restore NE default configuration: In the case of field debugging, various configurations of the
network element have been made. After debugging, in order to prevent some of the
configurations from being not restored, it needs to use this configuration to restore the network
element to the factory settings.
2.9.1. Save NE Configuration
Click on the NE which has been added
→
Click on“
NE Configuration
”on the right
→
Select“
Configuration Data
Save
”module and Click on“
Save
”.
Содержание M6500 Series
Страница 12: ...M6500 Series NE Configuration Manual 11 Figure 1 3 Start NMS Server...
Страница 63: ...M6500 Series NE Configuration Manual 62 Figure 4 34 Parameter Reading of WDM CFP2 Optical Transceiver...
Страница 105: ...M6500 Series NE Configuration Manual 104 Figure5 80 Site to Site Primary and Standby Protection Environment...
Страница 109: ...M6500 Series NE Configuration Manual 108 Figure6 5 TP Multiplexing Configuration Step 2...
Страница 113: ...M6500 Series NE Configuration Manual 112 Figure6 12 Set Line Side PM Overhead...
Страница 116: ...M6500 Series NE Configuration Manual 115 Figure6 16 Configure Line Side Port TTI...
Страница 117: ...M6500 Series NE Configuration Manual 116 Figure6 17 Configure Client Side Local End Port TTI...
Страница 118: ...M6500 Series NE Configuration Manual 117 Figure6 18 Configure Client Side Opposite End Port TTI...
Страница 129: ...M6500 Series NE Configuration Manual 128 Figure7 10 Select Protection Mode...
Страница 138: ...M6500 Series NE Configuration Manual 137 Figure8 14 Alarm Details Figure8 15 Alarm Document Link...