M6500 Series NE Configuration Manual
164
Figure9-53 Monitoring Data of SDH Regeneration Segment When Mismatched
9.2.6. Current Performance Statistics of Ethernet
9.2.6.1. Ethernet Monitoring Parameters Introduction
Monitoring parameters of Ethernet monitoring points include normal frame number, unicast frame number,
multicast frame number, broadcast frame number, CRC error frame, alignment error frame number, ultra-long
frame number (Frame Too Long), ultra-long Jabber frame number (CRC error), ultra-short frame number (CRC
error), discarded frame number, ultra-short frame number (CRC normal), 64-byte frame number. 65-127 byte
frame number, 128-255 byte frame number, 256-511 byte frame number, 512-1023 byte frame number,
1024-1518 byte frame number, 1519-maximum byte frame number, ultra-long frame number (CRC normal),
normal pause frame number (Pause), total frame number, suspicious interval marker, running time (S) and reset
operation. The performance parameters of Ethernet will be enabled or disabled at the same time.
Figure9-54 Ethernet Monitoring Parameters
9.2.6.2. View Ethernet Monitoring Information
As shown in the figure, select the appropriate network elements, slots, ports and monitoring cycle through the
selection box above the menu, the Ethernet value of a certain network element/slot/port will be displayed. The
monitoring point of Ethernet only includes the near end, and currently the monitoring directions include
entrance and exit. (Generally, the client port which is not OTU is corresponding to exit of ODU. The monitoring
direction of OTU and ODU for OTU port is entrance. Non-OTU means that the services of the port are not
OTU2/OTU2e.)
Optical module is inserted into the monitoring port. Ethernet monitoring data which is currently read will be
displayed. After the port is enabled, the suspicious interval marker should be untrustworthy. The running time
counts from 0. After 900 seconds, the suspicious interval marker will become trustworthy and the running time
counts again from 0. The last 15-minute data automatically becomes the history data.
Figure9-55 15-Minute Ethernet Monitoring Data
Optical module is inserted into the monitoring port. Ethernet data which is currently read will be displayed.
After the 24-hour performance monitoring port is enabled, the suspicious interval marker should be
untrustworthy. The running time counts from 0. After 86400 seconds, the suspicious interval marker will
Содержание M6500 Series
Страница 12: ...M6500 Series NE Configuration Manual 11 Figure 1 3 Start NMS Server...
Страница 63: ...M6500 Series NE Configuration Manual 62 Figure 4 34 Parameter Reading of WDM CFP2 Optical Transceiver...
Страница 105: ...M6500 Series NE Configuration Manual 104 Figure5 80 Site to Site Primary and Standby Protection Environment...
Страница 109: ...M6500 Series NE Configuration Manual 108 Figure6 5 TP Multiplexing Configuration Step 2...
Страница 113: ...M6500 Series NE Configuration Manual 112 Figure6 12 Set Line Side PM Overhead...
Страница 116: ...M6500 Series NE Configuration Manual 115 Figure6 16 Configure Line Side Port TTI...
Страница 117: ...M6500 Series NE Configuration Manual 116 Figure6 17 Configure Client Side Local End Port TTI...
Страница 118: ...M6500 Series NE Configuration Manual 117 Figure6 18 Configure Client Side Opposite End Port TTI...
Страница 129: ...M6500 Series NE Configuration Manual 128 Figure7 10 Select Protection Mode...
Страница 138: ...M6500 Series NE Configuration Manual 137 Figure8 14 Alarm Details Figure8 15 Alarm Document Link...