runtime (S) and reset operation.The performance parameters of OTUk / ODUk will be enabled or disabled at the
same time.
Figure9-37 OTUk/ODUk Monitoring Parameters
9.2.4.2. View OTUk/ODUk Monitoring Information
As shown in the figure, select the appropriate network elements, slots, ports and monitoring cycle through the
selection box above the menu, the OTUk/ODUk value of a certain network element/slot/port will be displayed.
The monitoring points of OTUk/ODUk include near end and far end, and the monitoring directions include
entrance and exit. (Generally, the client port which is not OTU is corresponding to exit of ODU. The monitoring
direction of OTU and ODU for OTU port is entrance. Non-OTU means that the services of the port are not
OTU2/OTU2e.)
Optical module is inserted into the monitoring port. OTUk/ODUk monitoring data which is currently read will be
displayed. After the port is enabled, the suspicious interval marker should be untrustworthy. The running time
counts from 0. After 900 seconds, the suspicious interval marker will become trustworthy and the running time
counts again from 0. The last 15-minute data automatically becomes the history data.
Figure9-38 15-Minute OTUk/ODUk Monitoring Data
Optical module is insertedw: into the monitoring port. OTUk/ODUk data which is currently read will be
displayed. After the 24-hour performance monitoring port is enabled, the suspicious interval marker should be
untrustworthy. The running time counts from 0. After 86400 seconds, the suspicious interval marker will
become trustworthy and the running time counts again from 0. The last 24-hour data automatically becomes
the history data, as shown in the figure belo
Содержание M6500 Series
Страница 12: ...M6500 Series NE Configuration Manual 11 Figure 1 3 Start NMS Server...
Страница 63: ...M6500 Series NE Configuration Manual 62 Figure 4 34 Parameter Reading of WDM CFP2 Optical Transceiver...
Страница 105: ...M6500 Series NE Configuration Manual 104 Figure5 80 Site to Site Primary and Standby Protection Environment...
Страница 109: ...M6500 Series NE Configuration Manual 108 Figure6 5 TP Multiplexing Configuration Step 2...
Страница 113: ...M6500 Series NE Configuration Manual 112 Figure6 12 Set Line Side PM Overhead...
Страница 116: ...M6500 Series NE Configuration Manual 115 Figure6 16 Configure Line Side Port TTI...
Страница 117: ...M6500 Series NE Configuration Manual 116 Figure6 17 Configure Client Side Local End Port TTI...
Страница 118: ...M6500 Series NE Configuration Manual 117 Figure6 18 Configure Client Side Opposite End Port TTI...
Страница 129: ...M6500 Series NE Configuration Manual 128 Figure7 10 Select Protection Mode...
Страница 138: ...M6500 Series NE Configuration Manual 137 Figure8 14 Alarm Details Figure8 15 Alarm Document Link...