background image

6

IMPORTANT: The SPEAKER OUT jack has an open load protection feature. If no cable is connected 

to this jack the Power Station will remain locked in BYPASS/STANDBY mode regardless of the 

front panel Standby switch setting. This is done to prevent potential damage to your valuable 

vintage amp should the speaker cable become disconnected while in Bypass mode. Use only a 

standard mono (tip/sleeve) 1/4“ phono plug.

11. CABINET IMPEDANCE – When the speaker jack is connected, simply set the impedance selector 

switch to match your cabinet.

IMPORTANT: The 2/4Ω amp and speaker setting is designed to be safe and compatible with all 

vintage 2Ω and 4Ω amplifiers. Because a reactive load is not an actual speaker, the impedance 

behavior of the load will not vary as wildly as an actual speaker and will therefore maintain a safe 

and stable load for your treasured vintage amps at this low impedance range. Even so, we do 

recommend that your power tubes are in good condition when using this device.

12. FOOTSWITCH JACK – Controls front panel Select function (tip) and FX loop bypass (ring) using 

any standard 2-function TRS latching footswitch or remote switch function provided by your pre-

amp, modeler or effects switching device. Shielded or non-shielded cable is suitable for this appli-

cation (Footswitch is sold separately).

13. GROUND LIFT – This switch separates the internal circuit ground from chassis and power ground 

in order to eliminate possible ground loops between the Power Station and the load amplifier 

connected to the AMP IN jack. Select the position which yields quietest operation. With a properly 

wired AC outlet and factory supplied AC cord, this switch may not produce a noticeable difference.

14. MAINS FUSE – Protects the amplifier from electrical faults. Replace only with type and rating spe-

cified on the rear panel of your amplifier.

15. AC MAINS INPUT – Connect to a grounded outlet in accordance with the voltage and frequency 

specified on the rear panel of your amplifier. 

 USE ONLY THE FACTORY SUPPLIED CORDSET OR A UL APPROVED EQUIVALENT TYPE

USING SILENT MODE

Silent Mode allows you to use the Power Station as a silent adjustable reactive load for quiet direct recor-

ding or when sending a live amp signal to front of house with no speaker cab connected. In this mode it is 

not necessary to power up the Power Station. You don’t even need to plug in the power cord. The Voicing 

switches, Low Pass Filter switch, FX Send (along with the FX Level switch), and the Balanced and Unba-

lanced Line Outputs all operate with no AC power applied.

TUBE FUNCTION AND LOCATION

Power and phase inverter tubes are mounted horizontally near the back of the unit. The power tubes are 

factory biased for optimum performance. No provision for internal or external biasing is provided. To insure 

that the Power Station will remain within safe temperature operating limits, the bias must not be modified 

or tampered with. Doing so will immediately void the warranty. Tube types are factory selected for superior 

performance, consistent tone quality and reliability. Power tubes are factory tested and matched. For best 

performance, replace only with factory recommended tubes.

Содержание Power Station 100

Страница 1: ...Power Station OWNERS MANUAL DUAL MODE VARIABLE REACTIVE LOAD TUBE POWER AMPLIFIER MODEL PS 100 www fryette com...

Страница 2: ...t the natural interaction between the speaker and power tube stage of your amplifier causing an artificial compressed sound and stiff feel The PS 100 is a 100 watt version of the award winning PowerSt...

Страница 3: ...en dropped or the enclosure damaged X X Do not drip or splash liquids nor place liquid filled containers on the unit X X CAUTION No user serviceable parts inside refer servicing to qualified personnel...

Страница 4: ...ttle more low end projection in your live or recorded mix NOTE These switches only operate when your load amplifier s speaker output is connected to the Power Station Amp In jack They remain operation...

Страница 5: ...nd jack for use with external effects processor This connec tion is post AMP IN and LINE IN so any effect connected here will be inserted between your load remotely engaged or bypassed with a footswit...

Страница 6: ...d the load amplifier connected to the AMP IN jack Select the position which yields quietest operation With a properly wired AC outlet and factory supplied AC cord this switch may not produce a noticea...

Страница 7: ...ED SERVICE PERSONNEL NO USER SERVICABLE PARTS INSIDE LINE LEVEL HI LO Amp Speaker Out Speaker Cab In XLR Line Out to mixer Standard to male speaker cable 1 Amp head to Power Station to Cab with effect...

Страница 8: ...mp Speaker Cab In Preamp Out to Line In 3 Preamp to Power Station Line In effect in loop and Power Station speaker out to speaker MAINS INPUT SERIAL 117 V SPKR OUT LIFT GROUND POWER STATION MODEL PS 1...

Страница 9: ...INE OUT FUSE MAIN T4A 50 60 HZ 300 WATTS AVIS RISQUES DE CHOC ELECTRIQUE NE PAS OUVRIR WARNING HAZARDOUS VOLTAGE INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL CAUTION DO NOT EXPOSE THIS EQUIPM...

Страница 10: ...nd and return cables are good and properly connected 2 Check footswitch remote switcher cable TRS RUNNING HOT 1 Make sure that the unit has adequate ventilation 2 Make sure that the impedance selector...

Страница 11: ...tive EC1907 206 for the Registration Evaluation Authorization and Restriction of chemicals REACh and contain none or less than 0 1 of the chemicals listed as hazardous chemicals in the REACh regulatio...

Страница 12: ...FD including but not limited to any malfunction defects or failure caused by or resulting from unauthorized service or parts damaged or broken tubes incorrect line voltage improper maintenance modific...