Displaying welding circuit inductivity L
General
Laying of the hosepacks has a significant effect on welding circuit inductivity and there-
fore affects the welding process. It is important to lay the hosepacks correctly in order to
obtain the best possible welding result.
Displaying weld-
ing circuit induct-
ivity
The setup parameter "L" is used to display the most recently calculated welding circuit
inductivity. The welding circuit inductivity is calibrated at the same time as the welding
circuit resistance is measured. Detailed information can be found in the "Measuring weld-
ing circuit resistance" section.
1
Access the Level 2 (2nd) Setup menu
2
Select parameter "L"
The most recently calculated welding circuit inductivity L is shown on the right-hand
digital display.
L
... Welding circuit inductivity (in microhenry)
Laying the
hosepacks cor-
rectly
92