![Fronius TransPocket 180 RC HW Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/fronius/transpocket-180-rc-hw/transpocket-180-rc-hw_operating-instructions-manual_2339428038.webp)
38
Technical Data
Grid voltage (U
1
)
1 x 240 V
Max. effective primary current (I
1eff
)
5 A
Max. primary current (I
1max
)
7 A
Mains fuse
16 A time-delay fuse
Grid voltage (U
1
)
1 x 120 V
Max. effective primary current (I
1eff
)
9 A
Max. primary current (I
1max
)
13 A
Mains fuse
15 A time-delay fuse
Grid voltage tolerance
-20%/+ 15%
Grid frequency
50/60 Hz
Cos phi
0.99
Recommended residual current circuit breaker
Type B
Pre-heating current range (I
2
)
10 – 180 A
Pre-heating current
10 min/40 °C (104 °F)
35%
60%
100%
U
1
(240 V)
180 A
155 A
125 A
U
1
(120 V)
170 A
155 A
125 A
Output voltage
6 V
Open circuit voltage (U
0
peak)
35 V
Degree of protection
IP 23
Type of cooling
AF
Overvoltage category
III
Degree of pollution according to standard IEC
60664
3
EMC device class
A
Safety symbols
S, CE
Dimensions L × W × H
435 x 160 x 310 mm
17.1 x 6.3 x 12.2 in.
Weight
8.9 kg
19.6 lb.