![Fronius TPS/i Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/fronius/tps-i/tps-i_user-information_2339420026.webp)
Process active
(Process active) -
Single Bit
The Process active signal is set from the beginning of gas pre-flow to the end of gas
post-flow in order to inform the robot that welding is still taking place. This means that,
for example, the dwell time of the robot can be synchronized at the end of the weld seam
to ensure that there is an ideal gas shield.
If the Welding start signal is set, the gas pre-flow time begins to count down, even before
the arc is ignited.
After extinguishing the arc, the gas post-flow time begins to count down.
I-S
I-E
I
GPr
GPo
SL1
Main current
SL2
t
t-S
t-E
High
Low
(1)
Welding start
(1)
Process active (process active)
Additional information for TWIN systems:
The signal is set as soon as one of the two power sources becomes active.
Current flow (cur-
rent flow) - Single
Bit
This signal is set as soon as the wire electrode touches the workpiece and current
begins to flow – the signal is High as soon as the workpiece is touched.
During welding the signal can fall to Low during all welding processes – the signal func-
tions in the same way for all welding processes.
I-S
I-E
I
GPr
GPo
SL1
Main current
SL2
t
t-S
t-E
High
Low
(1)
Welding start
(1)
Current flow (current flow)
Additional information for TWIN systems:
The signal is set to High as soon as one of the two wire electrodes becomes live.
26
Содержание TPS/i
Страница 2: ......
Страница 73: ...Reaction when limits are exceeded or undershot Warning Overview of the entries in the logbook 73 EN US...
Страница 77: ...Reaction when limit exceeded limit undershot error Error message 77 EN US...
Страница 83: ...Reaction when limits are exceeded or undershot Error Error message 83 EN US...