Connecting the battery to the inverter
Connecting the
battery on the DC
side
CAUTION!
Risk due to operation of the battery above the permissible altitude as specified by
the manufacturer.
Operating the battery above the permissible altitude can result in restricted operation,
failure of the operation, and unsafe states of the battery.
▶
Adhere to the manufacturer's instructions regarding the permissible altitude.
▶
Operate the battery only at the altitude specified by the manufacturer.
IMPORTANT!
Prior to installing a battery, ensure that the battery is switched off.
1
Manually guide the BAT cables through
the DC bushings.
* Connect the ground conductor of the
external battery (e.g. switch cabinet).
IMPORTANT!
Before stripping the insulation, push the
cables through the DC bushings to prevent
individual wires being bent or broken.