Selectiva 16 kW
Li-Ion
WARNING!
An electric shock due to a fault current can be fatal.
Nothing other than a type B residual current circuit breaker should ever be used
for connecting the device to the mains.
Mains voltage (-10% / +10%)
1)
Optional:
3~ NPE 400 V / 50/60 Hz
3~ PE 400 V / 50/60 Hz
Mains fuse protection
2)
32 A
Minimum mains lead cross section
6 mm² (0.0093 in²)
Duty cycle
100%
EMC device class
B
Protection class
1
Max. permitted mains impedance Z
max
on
PCC
3)
According to the "Device-spe-
cific data" table below
Degree of protection
4)
IP 20
Overvoltage category
III
Operating temperature
5)
-20 °C to +40 °C
(-4 °F to 104 °F)
Storage temperature
-25 °C to +80 °C
(-13 °F to 176 °F)
Relative humidity
maximum 85%
Maximum altitude above sea level
2000 m (6561 ft.)
Mark of conformity
according to rating plate
Product standard
EN62477-1
Dimensions l x w x h
647 x 247 x 392 mm
(25.47 x 9.72 x 15.43 in.)
Weight (with standard mains and charging
leads)
36.8 kg (81.13 lb)
Pollution degree
3
1)
The device is approved for operation on neutral-earthed mains networks
with a maximum outer conductor nominal voltage of 400 V.
2)
The earth leakage current is less than 3.5 mA.
3)
Interface to a 230/400 V, 50 Hz public grid
4)
For indoor use only, do not expose to rain or snow
5)
A high ambient temperature may result in power degradation (derating).
Device-specific data
Device
Max. AC
current
Max. AC
power
Nominal
voltage
Max. char-
ging cur-
rent
Z
max
Selectiva
8210
30.7 A
18,350 W
80 V
210 A
74
mOhm
54