Status codes
If a fault occurs during operation, specific status codes may be displayed. This
can be caused by the following:
-
Battery error
-
A battery with an unsuitable voltage has been connected.
-
The device has overheated.
-
A software or hardware error has occurred.
Battery error:
If the battery reports an error state, the battery charger will display this error as
a battery error including the corresponding error number of the battery. The re-
spective error explanation can be found in the Operating Instructions for the
battery.
If an error message appears on the display and the error cannot be rectified in-
dependently:
1
Note down the displayed status code: e.g., "Statecode (31)".
2
Note the configuration of the device.
3
Contact your authorized Service Partner.
If the device is in an error state, a freely defined text can be displayed, which
can contain the contact details of the distributor, for example.
Status codes with an external cause
No.
Cause / Remedy
(11)
Check mains voltage
(12)
Check grid (phase failure)
(13)
External temperature sensor defective
(14)
Electrolyte circulation defective (pressure switch does not switch)
(15)
No control voltage detected
(16)
External start/stop is not closed
.
(17)
Open circuit detection triggered several times during a charge (e.g.: worn
charging contacts)