97
EN
Explanation of Q-
Master wire feed
speed values
If the actual wire feed speed while job welding is greater than 15.5 m/min or less than 14.5
m/min for more than 0.3 sec, a reaction occurs in the form of a warning.
Wire feed speed command value
1)
E.g.:
15.0
m/min
-
Value for the lower wirefeed speed limit
-
0.5
m/min
=
upper welding current limit value
=
14.5
m/min
Wire feed speed command value
1)
E.g.:
15.0
m/min
+
Value for the upper wirefeed speed limit
+
0.5
m/min
=
upper wirefeed speed limit value
=
15.5
m/min
Maximum duration of current deviation
E.g.:
0.3
s
Reaction
2)
E.g.:
Warning
1)
According to "Working parameters" screen
2)
According to "QMaster" screen