In order to minimise the heating up of the inverter, do not expose it to
direct insolation. The inverter should be installed in a protected loca-
tion, for example, near the solar modules or under an overhanging
roof.
IMPORTANT!
The inverter must not be installed or used at altitudes
above 4000 m.
Do not install the inverter in:
-
Areas where it may be exposed to ammonia, corrosive gases,
acids or salts (e.g. fertiliser storage areas, vent openings for live-
stock stables, chemical plants, tanneries, etc.)
During certain operating phases the inverter may produce a slight
noise. For this reason it should not be installed in an occupied living
area.
Do not install the inverter in:
-
Areas where there is an increased risk of accidents from farm
animals (horses, cattle, sheep, pigs, etc.)
-
Stables or adjoining areas
-
Storage areas for hay, straw, chaff, animal feed, fertilizers, etc.
The inverter is essentially designed to be dustproof (IP 66). In areas of
high dust accumulation, dust deposits may collect on the cooling sur-
faces, and thus impair the thermal performance. Regular cleaning is
required in this case, see chapter
Operation in dusty environments
on page
. We therefore recommend not installing the inverter in
areas and environments with high dust accumulation.
Do not install the inverter in:
-
Greenhouses
-
Storage or processing areas for fruit, vegetables or viticulture
products
-
Areas used in the preparation of grain, green fodder or animal
feeds
Choosing the loc-
ation of third-
party batteries
IMPORTANT!
Refer to the manufacturer's documents for the suitable location for third-party batteries.
48
Содержание Primo GEN24 3.0 Plus
Страница 2: ......
Страница 11: ...General information 11...
Страница 12: ...12...
Страница 31: ...Backup power variant PV Point OP 31...
Страница 32: ...32...
Страница 34: ...34...
Страница 35: ...Backup power variant Full Backup 35...
Страница 36: ...36...
Страница 43: ...Installation 43...
Страница 44: ...44...
Страница 50: ...Do not install the inverter on the ceiling 50...
Страница 84: ...84...
Страница 90: ...90...
Страница 91: ...Settings website of the inverter 91...
Страница 92: ...92...
Страница 110: ...I O power man agement settings 4 relays 110...
Страница 112: ...I O power man agement settings 3 relays 112...
Страница 114: ...I O power man agement settings 2 relays 114...
Страница 118: ...118...
Страница 119: ...Options 119...
Страница 120: ...120...
Страница 129: ...Appendix 129...
Страница 130: ...130...
Страница 143: ...Circuit diagrams 143...
Страница 144: ...144...
Страница 145: ...Circuit Diagram PV Point OP Circuit Diagram 145 EN...
Страница 146: ...Fronius Primo GEN24 and BYD Battery Box Premium HV Circuit Diagram 146...
Страница 147: ...Automatic switch to backup power 1 pin double separation e g Austria Circuit Diagram 147 EN...
Страница 148: ...Automatic switch to backup power 1 pin single separation e g Australia Circuit Diagram 148...
Страница 149: ...Automatic switch to backup power 2 pin double separation e g Germany Circuit Diagram 149 EN...
Страница 150: ...Automatic switch to backup power 2 pin single separation e g France Spain Circuit Diagram 150...
Страница 151: ...Automatic switch to backup power 2 pin double separation e g UK Circuit Diagram 151 EN...
Страница 153: ...Fronius Primo GEN24 with Enwitec Box Circuit Diagram 153 EN...
Страница 154: ...Wiring diagram surge protective device SPD Circuit Diagram 154...
Страница 155: ...Dimensions of the inverter 155...
Страница 156: ...156...
Страница 157: ...Fronius Primo GEN24 3 6 kW Fronius Primo GEN24 3 6 kW 157 EN...
Страница 158: ...158...
Страница 159: ...159 EN...