150
Adjustable rod
electrode param-
eters
End-delay
Delay in the start of wirefeeding from end of the main current phase
Unit
s
Setting range
OFF / 0.1 - 9.9
Wire wdraw
Unit
mm
in.
Setting range
OFF / 1 - 50
OFF / 0.04 - 1.97
IMPORTANT!
Wire withdrawal prevents the welding wire from burning at the end. Before
the welding current is switched off, the wire is withdrawn to the set value. A prerequisite
for this function is that the arc has ignited.
Wire threading
Wire threading speed
Unit
m/min
ipm.
Setting range
0.1 - max.
3.94 - max.
Main current
Unit
A
Setting range
MW 2500 Comfort 3 - 250
MW 3000 Comfort 3 - 300
TT 2500 Comfort 3 - 250
TT 3000 Comfort 3 - 300
Arc-force dynamic
In order to obtain optimum welding results, it will sometimes be necessary to set the arc-
force dynamic function.
Unit
% (of main current)
Setting range
0 - 100
0
soft, low-spatter arc
100
harder, more stable arc
Functional principle:
at the instant of droplet transfer or when a short circuit occurs, there is a momentary rise
in amperage. In order to obtain a stable arc, the welding current is temporarily increased.
If the rod electrode threatens to sink into the weld pool, this measure prevents the weld
pool solidifying, as well as preventing more prolonged short circuiting of the arc. This
largely prevents the rod electrode from sticking.
Jobslope
For changing to another job during welding. Jobslope is the time that it takes for the weld-
ing current to adjust seamlessly from the present job to the next.
Unit
s
Setting range
Off / 0.1 - 9.9
NOTE!
Switching over from one job to the next without interrupting welding is only
possible with a JobMaster TIG welding torch, robot interface or field bus.
Starting current
Unit
% (of main current)
Setting range
30 - 200 AC, 0 - 200 DC
Содержание MagicWave 2200 Comfort
Страница 2: ...2...
Страница 4: ...4...
Страница 10: ...10...
Страница 23: ...General information...
Страница 24: ......
Страница 27: ...Control elements and connections...
Страница 28: ......
Страница 39: ...Installation and commissioning...
Страница 40: ......
Страница 45: ...Welding...
Страница 46: ......
Страница 89: ...Setup settings...
Страница 90: ......
Страница 170: ...170...
Страница 171: ...Troubleshooting and maintenance...
Страница 172: ......
Страница 183: ...183 EN Disposal Dispose of in accordance with the applicable national and local regulations...
Страница 184: ...184...
Страница 185: ...Appendix...
Страница 186: ......
Страница 195: ...Spare parts and circuit diagrams...
Страница 196: ...196 Spare parts list TransTig MagicWave 2200 Comfort...
Страница 197: ...197...
Страница 198: ...198 Spare parts list TransTig MagicWave 2500 3000...
Страница 200: ...200 Spare parts list TransTig 4000...
Страница 201: ...201...
Страница 202: ...202 Spare parts list MagicWave 4000...
Страница 203: ...203...
Страница 204: ...204...
Страница 205: ...205 Circuit diagrams MagicWave 2200 Comfort V 12 06 2014...
Страница 206: ...206 Circuit diagrams MagicWave 2500 Comfort...
Страница 207: ...207 Circuit diagrams MagicWave 3000 Comfort...
Страница 208: ...208 Circuit diagrams MagicWave 4000 Comfort V 17 12 2012 1 2...
Страница 209: ...209 V 17 12 2012 2 2...
Страница 210: ...210 Circuit diagrams TransTig 2200 Comfort V 14 12 2010...
Страница 211: ...211 Circuit diagrams TransTig 2500 Comfort...
Страница 212: ...212 Circuit diagrams TransTig 3000 Comfort...
Страница 213: ...213 Circuit diagrams TransTig 4000 Comfort V 17 12 2012...
Страница 214: ......
Страница 215: ......