18
Controls, connections and mechanical components
Safety
WARNING!
Danger from incorrect operation.
Possible serious injury and damage to property.
► Do not use the functions described here until you have read and completely under
-
stood these Operating Instructions.
► Do not use the functions described here until you have fully read and understood all of
the Operating Instructions for the system components, in particular the safety rules!
Controls
Controls
(1)
Cleaning-current dial
continuous adjustment of cleaning current from 5-20 A
(2)
Program switch
for switching the MagicCleaner from stand-by to the desired operating mode.
(3)
LED indicator “Auto-Cleaning“ mode
lights up when the “Auto-Cleaning“ mode is selected
(4)
LED indicator “Manual-Cleaning“ mode
lights up when the “Manual-Cleaning“ mode is selected
(5)
Dial for electrolyte dispensing rate
continuous adjustment of electrolyte dispensing rate from 0.55 - 2.2 l/h
(6)
“Elektrolyte dispensing” LED
lights up when the pump is in operation
(7)
LED “Fault” indicator
-
lights up if the unit is overloaded (if the temperature of the power section reaches
65°C).
-
flashes if short-circuiting occurs between the stylus and earth (e.g. cleaning cloth
is defective)