Safety
WARNING!
Danger from electrical current.
This can result in serious personal injury and damage to property.
▶
Before starting work, switch off all devices and components involved and disconnect
them from the grid.
▶
Secure all devices and components involved so they cannot be switched back on.
▶
After opening the device, use a suitable measuring instrument to check that electric-
ally charged components (such as capacitors) have been discharged.
Connecting the
KD Supply 2500
to the cooling
unit and power
source
(1)
(1)
(1)
(1)
(2)
(2)
(2)
(2)
1
Turn the power source mains switch to
the „O“ position
2
Unplug power source mains plug
3
Remove protective cover from the un-
derside of the power source
4
Firmly press four M5 hexagonal nuts
(supplied with the KD Supply 2500)
from the inside into the hexagonal re-
cesses (1) in the fastening bars
If a cooling unit is present:
5
Remove the protective cover from the
underside of the KD Supply 2500
6
FIrmly press four M5 hexagonal nuts
(supplied with cooling unit) from the in-
side into the hexagonal recesses (2) in
the fastening bars
7
Hold the KD Supply 2500 over the
cooling unit
8
Pull the KD Supply 2500 connector as
far as possible through the opening on
the underside of the power source
9
Establish connection between KD
Supply 2500 and cooling unit
CAUTION!
Risk of short circuit from kinked or damaged cables.
This can result in serious personal injury and damage to property.
▶
When positioning the KD Supply 2500, ensure that the cables are not kinked.
9