Proper use
The solar inverter is exclusively intended for charging a battery with direct cur-
rent from solar modules, or for converting this direct current into alternating
current and feeding it into the public grid or the household network in emer-
gency power mode.
The following actions constitute improper use:
-
Any use above and beyond this purpose
-
Making any modifications to the inverter that have not been expressly ap-
proved by Fronius
-
Installing components that are not distributed or expressly approved by
Fronius
-
Operating the device with a battery that has not been approved by Fronius
-
Operating the equipment with an energy meter that has not been approved
by Fronius
Fronius shall not be liable for any damage resulting from such action.
No warranty claims will be entertained.
Proper use also includes:
-
Carefully studying and obeying the Installation and Operating Instructions
-
Performing all stipulated inspection and maintenance work
When designing the photovoltaic system, ensure that all of its components are
operated within their permitted operating ranges at all times.
Observe all the measures recommended by the solar module manufacturer to
ensure that the solar module retains its properties in the long term.
Observe the stipulations of the power supply company concerning energy fed in-
to the grid, emergency power mode and the operation of storage systems.
The Fronius Symo Hybrid is a grid-connected inverter with an emergency power
function – it is not a stand-alone inverter. The following restrictions must there-
fore be observed in emergency power mode:
-
Emergency power mode may be in operation for at least 1500 hours
-
Emergency power mode may be in operation for more than 1500 operating
hours if 15% of the duration of the inverter's grid power feed operation is not
exceeded at the relevant time
Warning notices
on the device
There are warning notices and safety symbols on and in the inverter. These warn-
ing notices and safety symbols must not be removed or painted over. They warn
against incorrect operation, as this may result in serious injury and damage.
14
Содержание Energy Package
Страница 1: ...Operating Instructions Fronius Energy Package 42 0426 0222 EN 024 05052022 EN Operating Instructions...
Страница 2: ......
Страница 10: ...10...
Страница 11: ...General information 11...
Страница 12: ...12...
Страница 36: ...ON OFF 2 3 Switch on the automatic circuit break er Set the DC disconnector to the On switch position 36...
Страница 37: ...Operation 37...
Страница 38: ...38...
Страница 69: ...Fronius system monitoring 69...
Страница 70: ...70...
Страница 82: ...82...
Страница 83: ...Current data services and settings offered by Fronius system monitor ing 83...
Страница 84: ...84...
Страница 121: ...Troubleshooting and maintenance 121...
Страница 122: ...122...
Страница 136: ...136...
Страница 137: ...Appendix 137...
Страница 138: ...138...
Страница 145: ...145 EN...
Страница 146: ...146...
Страница 147: ...147 EN...
Страница 148: ......