Technical data
Environmental
conditions
Transport, storage or operation of the device outside the stipulated range will be
deemed improper. The manufacturer shall not be held liable for any damage
arising from such usage.
Ambient air temperature range:
-
During operation: -10 °C to + 40 °C (14 °F to 104 °F)
-
During transport: -20 °C to +55 °C (-4 °F to 131 °F)
-
Recommended temperature range during charging:
+ 4 °C to + 40 °C (+ 39.2 °F to + 104 °F)
-
Recommended temperature range during storage:
0 °C to + 20 °C (+ 32 °F to + 68 °F)
When placing in storage, the state of charge should ideally be at 50 - 80%
(corresponds to approx. 2 to 3 bars on the charging status indication).
Relative humidity:
-
Up to 50% at 40 °C (104 °F)
-
Up to 90 % at 20 °C (68 °F)
The surrounding air must be free from dust, acids, corrosive gases or substances,
etc.
Can be used at altitudes up to 2000 m (6561 ft.)
Explanation of
the term "duty
cycle"
Duty cycle (ED) is the proportion of time in a 10-minute cycle at which the device
may be operated at its rated output without overheating.
NOTE!
The ED values specified on the rating plate are based on an ambient temperat-
ure of 40 °C.
If the ambient temperature is higher, either the ED or output must be reduced
accordingly.
Example: Welding at 150 A at 60% ED
-
Welding phase = 60% of 10 minutes = 6 minutes
-
Cooling phase = remaining time = 4 minutes
-
After the cooling phase, the cycle begins again.
66
Содержание AccuPocket 150/400 TIG
Страница 2: ......
Страница 6: ...6...
Страница 7: ...Safety rules 7...
Страница 8: ...8...
Страница 24: ...24...
Страница 25: ...Power source 25...
Страница 26: ...26...
Страница 28: ...Application areas MMA welding TIG welding 28...
Страница 56: ...Every 2 months Clean the air filter if fitted 1 56...
Страница 69: ...Charger 69...
Страница 70: ...70...
Страница 84: ...84...
Страница 85: ...85 EN...
Страница 86: ...86...
Страница 87: ...87 EN...