Parameters for
TIG welding
Operating mode (trigger mode)
OFF / 2t / 4t
-
Operation using welding torch without a torch trigger
-
2-step mode
-
4-step mode
Factory setting: 2t
Starting current (I-Start)
1 - 200 percent
This parameter is only available in 4-step mode (
tri
= 4t).
Factory setting: 50 %
Reduced current
1 - 200 percent
This parameter is only available in 4-step mode (
tri
= 4t).
Factory setting: 50 %
Final current (I-End)
1 - 100 percent
This parameter is only available in 4-step mode (
tri
= 4t).
Factory setting: 50 %
Gas post-flow time (Gas Post flow)
0.2 - 9.9 seconds
Specified period during which gas flows at the end of welding.
Factory setting: 9.9 seconds
Comfort Stop Sensitivity (Comfort Stop Sensitivity)
0.3 - 2.0 V / OFF
This parameter is only available when the
tri
parameter is set to OFF.
Factory setting: OFF
For details see the
section from page
.
52