5 | Installation
26
M2050222_en | Installation instructions Lambdamat LM 1500 KOM
5.6.5 Installing the air controllers
r
Remove the blanking plate from the two secondary air boxes (A) and the primary air
box (B).
r
Insert the air damper in the air box.
Ä
Short air damper shaft: secondary air box (A)
Ä
Long air damper shaft: primary air box (B)
r
Screw the stop screw (C) into the air boxes so that the air damper touches the thread.
r
Re-fit the blanking plate to the air boxes.
r
Fit the torque supports to the air damper shafts.
r
Remove the blanking plate and replace it with the pipe with seal (A).