4.3.6 Fitting the rotary agitator
❒ Assemble three-part rotary agitator duct (A)
➥ Check alignment of flange plates!
❒ Slide drive shaft (B) into rotary agitator duct
❒ Push rotary agitator duct through hole in wall
➥ The last part must be positioned close to the hole in the wall!
❒ Grease shaft stub of drive shaft and bearing shaft of mitre gear with copper paste
❒ Fit flange plate (C), counter flange for torque support and flange bearing (D) to
rotary agitator duct
❒ Fit mitre gear (E) to flange of rotary agitator duct
➥ Thread bearing shaft of mitre gear correctly into drive shaft!
Prepare the geared motor:
❒ Remove the transport lock
❒ Fit the vent screw (supplied) to the highest point