29
11.2 Maintenance Intervals
11.3 Troubleshooting Table
Interval
Model
Maintenance Task
Chapter
Once a day
All
Check the oil level.
See
Chapter 10.4, "Oil Level Check," page 15
.
Once a day
"Sealing and Quenching Liquid"
option
Check the sealing or quenching liquid.
Chapter 10.3, "Inspection of Sealing and Quen-
ching Liquid (Optional)," page 15
.
2,000 h
All, under severe operating condi-
tions
Change the oil.
See
Chapter 10.5, "Oil Change," page 15
.
4,000 h
All
Check the displacer nut/screw for tightness
and retighten if necessary
See
Chapter 10.13, "Checking of the Clearances,"
4,000 h
All, under normal operating condi-
tions
Change the oil.
See
Chapter 10.5, "Oil Change," page 15
.
When necessary
All
Replace the shaft seal.
See
Chapter 10.7, "Shaft Seal Replacement,"
When necessary
All
Replace the coupling.
See
Chapter 10.11, "Coupling Replacement,"
When necessary
All
Replace the motor.
See
Chapter 10.12, "Gear Motor Replacement,"
According to
manufacturer's
specifications
All
Lubricate the motor bearings;
For additional maintenance intervals for the
motor, please see the motor supplier docu-
mentation.
See
Chapter 10.6, "Lubrication of Motor Bearings,"
Table 26 Maintenance intervals
Problem
Possible Cause
Remedy
Pump either does not pump or pumps
irregularly.
Pump interior not completely filled with liquid;
pump interior not vented; discharge valve closed.
Fill pump interior with liquid;
open discharge valve.
Suction line blocked or clogged.
Open or clean suction line.
Pump with geodesic suction head
1
: liquid
falls at standstill and casing runs dry.
Install foot valve in suction line.
Suction line leaky; seal on pump cover leaky and
drawing in air.
Seal suction line; replace cover seal.
Air pocket in suction line.
Lay suction line as straight as possible and at
steady incline.
Pump blocked; foreign objects in pump.
Clean pump interior; perform visual inspection;
consult
Fristam
.
Viscosity of pumping medium too high;
medium does not flow well because too viscous.
Consult
Fristam
.
Coupling punctured due to
overloading.
Consult
Fristam
.
Flow rate too high.
Pump oversized.
Consult
Fristam
.
No regulating valve behind discharge port.
Install regulating valve; add throttle control;
reduce motor speed.
Flow rate too low; discharge head too low.
Selected pump too small; motor speed too low
due to incorrect voltage.
Consult
Fristam
;
connect according to motor rating plate.
Suction line leaky and drawing in air.
Seal leakiness.
Viscosity of pumping medium too high (too vis-
cous).
Possibly convert to heating; consult
Fristam
.
Rotor wear; clearance too large.
Repair.
Back pressure too high; relief valve (if supplied)
regulates incorrectly.
Set relief valve correctly.
Direction of rotation incorrect.
Correct pipe and electrical connections.
Table 27 Troubleshooting table