PRE-INSTALLATION REQUIREMENTS

Tools Required for Installation:

1. Phillips screwdriver
2. 10 mm socket with ratchet.
3. Channel-lock adjustable pliers.
4. Carpenter’s level.

ELECTRICAL REQUIREMENTS

CIRCUIT

 - Individual, properly polarized and grounded 15 amp.

branch circuit fused with 15 amp. time delay fuse or circuit breaker.

POWER SUPPLY

 - 2 wire, with ground, 120 volt, single phase, 60

Hz, Alternating Current.  

NOTE:

 Because of potential inconsistent

voltage capabilities, the use of this washer with power created by
gas powered generators, solar powered generators, wind powered
generators or any other generator other than the local utility
company is not recommended.

OUTLET RECEPTACLE

 - Properly grounded 3-prong receptacle to

be located so the power supply cord is accessible when the washer
is in an installed position. 

NOTE: 

GFI (Ground Fault Interrupter)

receptacle is not required.

24 in.

(61 cm)

Min.

96 in.

(244 cm)

Max.

BACK

absence of local codes, with the National Electrical
Codes, ANSI/NFPA 70 (latest edition). If in doubt,
call a licensed electrician. 

DO NOT

 cut off or alter

the grounding prong on the power supply cord. In
situations where a two-slot receptacle is present,
it is the owner’s responsibility to have a licensed
electrician replace it with a 

properly grounded

three prong grounding type receptacle.

WATER SUPPLY REQUIREMENTS

Hot and cold water faucets 

MUST

 be installed within

42 inches (107 cm) of your washer’s water inlet. The
faucets 

MUST

 be 3/4 inch (1.9 cm) garden hose type

so inlet hoses can be connected. Water pressure 

MUST

be between 30 and 120 pounds per square inch (maximum
unbalance pressure, hot vs. cold, 10 psi.) Your water
department can advise you of your water pressure.

DRAIN REQUIREMENTS

1.

Drain capable of eliminating 17 gals (64.3 L) per
minute.

2.

A standpipe diameter of 1-1/4 in. (3.18 cm)
minimum.

3.

The standpipe height above the floor should be:

Minimum height:

24 in. (61 cm)

Maximum height:

96 in. (244 cm)

NOTE:

Drain hose attached to the washer can reach a 

79

in. (2

01

 cm) high standpipe. For higher standpipe,

use hose P/N 

134

8896

10

, available from an

authorized parts distributor.

GROUNDING REQUIREMENTS

Improper connection of the equipment grounding

conductor can result in a risk of electrical shock. Check with a
licensed electrician if you are in doubt as to whether the appliance
is properly grounded.

1.

The washer 

MUST

 be grounded. In the event of malfunction

or breakdown, grounding will reduce the risk of electrical shock
by a path of least resistance for electrical current.

2.

Since your washer is equipped with a power supply cord having
an equipment-grounding conductor and a grounding plug, the
plug 

MUST

 be plugged into an appropriate, copper wired

receptacle that is properly installed and grounded in accordance
with all local codes and ordinances or in the

Before beginning installation, carefully read these
instructions. This will simplify the installation and ensure
the  washer is installed correctly and safely. Leave these
instructions near the washer after installation for future
reference.

NOTE: The electrical service to the washer must conform with
local codes and ordinances and the latest edition of the
National Electrical Code, ANSI/NFPA 70.

Содержание LTF2940FE

Страница 1: ...fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Pour votre sécurité suivre les directives données dans le présent guide afin de minimiser les risques d incendie d explosion de dommages matériels de blessures et de mort Ne pas entreposer ni utiliser d essence ou d autres vapeurs ou liquides inflammables à proximité de cette séch...

Страница 2: ...et hoses can be connected Water pressure MUST be between 30 and 120 pounds per square inch maximum unbalance pressure hot vs cold 10 psi Your water department can advise you of your water pressure DRAIN REQUIREMENTS 1 Drain capable of eliminating 17 gals 64 3 L per minute 2 A standpipe diameter of 1 1 4 in 3 18 cm minimum 3 The standpipe height above the floor should be Minimum height 24 in 61 cm ...

Страница 3: ... the pedestal For stacking installations see additional installtion instructions included with the stacking kit For under counter installations no special top is required ROUGH IN DIMENSIONS inches cm inches cm inches cm inches cm inches cm inches cm inches cm inches cm inches cm inches cm ...

Страница 4: ...lope of 1 2 in per foot 1 27 cm per 30 5 cm To ensure vibration or movement does not occur reinforcement of the floor may be necessary IMPORTANT MINIMUM INSTALLATION CLEARANCES When installed in alcove or closet Sides Rear 0 in 0 cm Top 0 in 0 cm When installed in closet Front 1 in 2 54 cm Closet door ventilation required 2 louvered openings each 60 in2 387 cm2 3 in 7 6 cm from top and bottom of d...

Страница 5: ...erature pack located in the drum and install them in the holes vacated by the packaging spacers NOTE If the washer is to be transported at a later date the shipping support hardware must be reinstalled to prevent shipping damage Washer Connections 1 Run some water from the hot and cold faucets to flush the water lines and remove particles that might clog up the water valve screens 2 Remove the inl...

Страница 6: ... washer Pedestal A pedestal accessory Model No NLPWD15 White NLPWD15GB GlacierBlue NLPWD15P Platinum andNLPWD15E Black specifically designed for this washer may be used when elevating the washer for ease of use Failure to use accessories certified by the manufacturer could result in personal injury property damage or damage to the washer REPLACEMENT PARTS If replacements parts are needed for your ...

Страница 7: ...he DOIT être branchée dans une prise murale à conducteur en cuivre conven ablement raccordée au réseau et mise à la terreconformémentàtouslescodesetordonnances locaux ou s il n existe pas de codes locaux conformément au Code ANSI NFPA 70 l édition la plus récente En cas de doute contacter un électricien agréé NE PAS couper ni modifier la broche de mise à la terre du cordon d alimentation électriqu...

Страница 8: ... d alimentation Boyau d évacuation NOTE Pour les installations de piédestal Voir les instructions d installation supplémentaires incluses avec le piédestal NOTE Pour les installations de superposition Voir les instructions d installation supplémentaires incluses avec le kit de superposition NOTE Pour les Pour des installations d undercounter aucun dessus spécial n est exigé ...

Страница 9: ...um de 1 27 cm par 30 5 cm 1 2 po par pied Pour éviter toute vibration ou tout mouvement il peut être nécessaire de renforcer le plancher IMPORTANT DÉGAGEMENTSMINIMAUXPOURL INSTALLATION Installation en alcôve ou armoire Côtés Arrière 0 cm 0 po Dessus 0 cm 0 po Installation en armoire Avant 2 54 cm 1 po Ventilation requise dans la porte du placard 2 ouvertures chacune 2 volets de 387 cm2 60 po2 chac...

Страница 10: ...ES quatre jambes Gardez la prolonga tion de mise à niveau de jambe à un minimum pour la meilleure exécution de la laveuse 2 Pour des installations de piédestal Voir les instructions d installation additionnelles incluses avec le piédestal Raccordements De Laveuse 1 Ouvrir les robinets d eau chaude et d eau froide de façon à nettoyer la canalisation et à éliminer toute particule qui pourrait engorg...

Страница 11: ...nt de la laveuse bas de la laveuse et serrer solidement avec une clé Piédestal Un accessoire de piédestal N de Modèle NLPWD15 Blanc NLPWD15P Graphite NLPWD15GB Bleu Glacier et NLPWD15E Noir a spécifiquement conçu pour cette laveuse peut être utilisé en élevant la laveuse pour la facilité d utilisation Le manque d utiliser des accessoires certifiés par le fabricant a pu avoir comme conséquence des ...

Страница 12: ...stalada correctamente y de manera segura Guarde estas instrucciones cerca de la lavadora una vez terminada la instalación para referirse a ellas en el futuro NOTA el suministro eléctrico de su lavadora debe estar conforme con los códigos y ordenanzas locales y la edición más reciente del National Electrical Code Código Eléctrico Nacional ANSI NFPA70 REQUISITOS ANTES DE LA INSTALACION Herramientasn...

Страница 13: ... Nota Para instalaciones de pedestal vea las instrucciones adicionales de instalación incluidas con el pedestal Para instalaciones apiladas vea las instrucciones adicionales de instalación incluidas en el paquete para apilar stacking kit Para instalaciones debajo de una mesa o base no se requiere ninguna tapa o cubierta especial ...

Страница 14: ...se de que no existan vibraciones ni ruidos puede ser necesario reforzar el piso IMPORTANTE CLAROS MINIMOS DE INSTALACION Instalación en un armario Lados Parte Trasera Parte Superior 0 cm 0 pulg Parte Delantera 2 54 cm 1 pulg Aberturas de ventilación requeridas en la puerta del armario Dos rejillas de ventilación cada 387 cm 60pulg 7 6 cm 3 pulg desde la parte inferior y superior de la puerta DESEM...

Страница 15: ...atas de forma apropiada hasta que la lavadora este bien sentada de manera SÓLIDA sobre el piso Trate de tener las patas niveladoras lo menos extendidas de la lavadora posible para un mejor funcionamiento de la lavadora 2 Para las instalaciones del pedestal vea las instrucciones de instalación adicionales incluidas con el pedestal CONEXIONES DE LA LAVADORA 1 Deje correr un poco agua de las llaves d...

Страница 16: ...on el cincho proporcionada dentro del paquete al tubo del drenaje a la alimentación de agua a la tubería de la entrada a la tina del lavadero etc para que la manguera no se salga con la fuerza del agua 7 Enchufe el cable tomacorriente en un contacto debidamente aterrizado NOTA Asegúrese de que la corriente esté cortada en el interruptor caja de fusibles antes de enchufar el cable en el tomacorrien...